Cable routing
www.zepro.com
Image 66.
Calculation of minimum conductor cross sectional area
ZN 2500 (200 bar)
Hydraulic unit 7100
12 volt
24 volt
Pump - Motor unit
145 A
Magnet (hydraulic unit)
2.1 A
Magnet (electric safety valve)
0.75 A
Solenoid
0.9 A
Minimum recommended conductor cross sectional area
(copper cables, plus and minus cables)
Control cable
1.5 mm
2
Supply cable, L < 8 m
35 mm
2
Supply cable, L = 8 - 15 m
35 mm
2
Supply cable, L > 15 m
50 mm
2
Battery
Min. capacity, I
min
170 Ah
Min. voltage during operation, U
min
(at lift)
18 Volt
-
+
-
+
L
L
U
min
I
min
I
min
U
min
5.2
Maximum power consumption - Minimum recommended conductor
cross sectional area
5.3
Battery maintenance
When storing for longer than 1 week, you are recommended to disconnect the lift from the battery via the
main switch or by releasing the lift’s main fuse, in order to reduce the risk of the battery discharging. The
length of time the vehicle can be stored without the battery’s charge level becoming too low depends on the
condition of the battery, the charge level before storage and how much power the vehicle’s other components
take from the battery. After a period of storage, the battery must always be charged fully before operating the
lift.
When installing the lift and when carrying out service and repair work, when the lift is operated repeatedly
without the vehicle being started and used, the battery charger must be used between operations to maintain
the battery’s charge level.
NOTE!
The battery charger must not be connected when operating the lift. Risk of damage.
OBSERVERA!
Ensure that the lift has access
to the minimum recommended
power capacity (I
min
). Some
vehicles have restrictions
regarding the amount of power
the lift can access from the
existing battery.