ZHD 2500-130/150
Installation
27
www.zepro.com
6.12
Platform
1. Check that all included components are clean,
cleaning them where necessary.
2. Lubricate the metal bushings on the upper bearing
of the arms. Ensure that the small holes on the
inside of the bushings are filled with grease. See
Image 38. Use Zepro lubricant or the equivalent.
Carefully lubricate the metal bushings on the
upper bearing of the arms. Ensure that the small
holes are filled with grease. After the platform is
fitted, lubricate all bearings via normal grease
nipples, see section "13 Lubrication and fluid
level check" on page 59.
NOTE.
3. Fit the platform to the arms using the supplied shafts
and screws. Tighten the bolts using a torque wrench.
Tightening torque: 80 Nm.
NOTE!
Lubricate the
bushings
4. Fit one of the tilt cylinders to the platform.
Use the supplied shaft and support wheel.
Make sure the cylinder is installed with the
grease nipple facing up.
NOTE.
Tighten the bolts using a torque wrench.
Tightening torque: 80 Nm.
Image 38. Carefully lubricate the metal bushings
Image 39. Fitting the platform to the arms
Image 40. Fitting the tilt cylinder to the platform
Содержание ZHD 2500-130
Страница 2: ......
Страница 65: ...ZHD 2500 130 150 Specifications 65 www zepro com Image 71 Loading diagram 16 4 Loading diagram...