Features & Controls – 

User Interface

14

www.zephyronline.com

Mesh Filter Clean Indicator 

(always enabled)

 - After 30 hours of fan usage the      Graphic and words “

clean mesh filter

” will illuminate indicating it is time to clean

   the mesh filters. Graphic and words will remain illuminated until reset.
 - 

To reset:

 With hood off, hold the      Button for three seconds, after three seconds the       Graphic and words “

clean mesh      

    filter

” will turn off and the 30 hour timer will reset.

Charcoal Filter Replace Indicator

 

(disabled by default, must be enabled if recirculating hood)

 - To enable Charcoal Filter Replacement Function:
 

- With hood off, hold       Button and       Button simultaneously for three seconds. The       Graphic will illuminate for  

 

  three seconds indicating the Charcoal Filter Replacement Function is enabled.

 - To disable Charcoal Filter Replacement Function:
 

- With hood off, hold       Button and       Button simultaneously for three seconds. The        Graphic will be  

 

 

   illuminated then turn off indicating the Charcoal Filter Replacement Function is disabled.

 - After 120 hours of fan usage the       Graphic and words “

replace charcoal filter

” will illuminate indicating it is time to  

   replace the charcoal filter. 

Graphic and words will remain illuminated until reset.

 - 

To reset: 

With hood off, hold the       Button for three seconds, after three seconds the        Graphic and words “

replace  

    charcoal filter

” will turn off and the 120 hour timer will reset.

Clean Air Indicator

 - Clean Air is a feature that turns the fan on every 4 hours for 10 minutes to remove stagnant air in the kitchen.
 

- To enable Clean Air Function:

 

 

- With hood off, hold the      Button and       Button simultaneously for three seconds. The       Graphic and  

 

 

   words “

clean air

” will illuminate and the fan will turn on speed 1 for 10 minutes. After 10 minutes the fan  

 

 

   will turn off and the 4 hour timer will begin.

 

 

-       Graphic will remain on when Clean Air Function is enabled, even if fan is not on.

 

- To disable Clean Air Function:

 

 

- With hood off, hold the       Button and       Button simultaneously for three seconds until       Graphic  

 

 

  turns off.

 - When the Clean Air Function is enabled the fan will turn on speed 1 for 10 minutes every 4 hours of non fan usage. After 10 
   minutes the fan will turn off and the 4 hour timer will reset.
 - If the user changes the fan speed while the Clean Air Function is in use, the words “

clean air

” will turn off but the      Graphic  

   will remain illuminated. If the user presses the      Button at any time the 4 hour clean air timer will reset.

Содержание ZML-E42BG

Страница 1: ...Use Care and Installation Guide Model number Serial Number MAY11 0201 Zephyr Corporation Milano Island ZML M90BG ZML M90BS ZML E42BG ZML E42BS www zephyronline com ...

Страница 2: ...www zephyronline com ...

Страница 3: ...ht Clearance 6 Ducting Options 7 Hood Specifications 8 Mounting the Hood 9 11 Ductless Recirculating 12 FEATURES CONTROLS Touch Controls 13 User Interface 14 MAINTENANCE Hood and Filter Cleaning 15 TROUBLESHOOTING 16 WIRING FAN CURVE DIAGRAMS 17 LIST OF PARTS AND ACCESSORIES 18 Table of Contents ...

Страница 4: ...PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result...

Страница 5: ...t the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Do not ground ...

Страница 6: ...lower pre installed 1 Canopy glass or stainless 2 Aluminum mesh filters 4 3W LED lights 1 8 round damper pre installed MODELS ZML M90BG BS ZML E42BG BS PARTS SUPPLIED HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if required by local codes Duct cover extension accessory Recirculating kit accessory 4 3 16 x 8 canopy screws A B Front of Hood ...

Страница 7: ...uct pieces T otal Equivalent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round roof cap 30 Ft x Ft 7 or 8 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length o...

Страница 8: ...mance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Duct cover extension kit available for ceiling heights up to 12 feet Turn to page 18 for part number and ordering information DAMAGE SHIPMENT INSTALLATION Please fully inspect unit for damage before inst...

Страница 9: ...utside unless using the recirculating option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Installation Ducting Options side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap ductless recirculating blower housing blower housing blower housing ...

Страница 10: ... TOP SUPPORT FRAME top view C L 9 11 16 10 9 16 4 13 16 5 8 7 15 16 1 1 4 4 AC In 2 3 16 C L C L 12 15 16 35 5 16 42 9 11 16 14 1 8 6 11 16 23 15 16 STANDARD min ducted 28 1 2 min recirc 32 1 2 max 50 Z1C 03ML min ducted 44 min recirc 48 1 2 max 82 12 3 4 25 9 16 10 15 16 5 5 16 ...

Страница 11: ...installed inside the support frame FIG C 1 Upper support frame arms extend past lower support frame bracket with shorter hood heights FIG C 2 3 Lift support frame assembly up to the ceiling making sure the the word front on the top support frame faces the front of the hood where the controls will be located FIG C The key holes on the top support frame should cover the wood screws previously instal...

Страница 12: ...d align the 4 pre installed mounting screws on top of blower housing FIG A 5 on Page 9 with the 4 key holes on the bottom of the support frame FIG F Slide hood towards the narrow end of key holes to lock in place Hand tighten each of the 4 screws to secure hood to bottom of support frame Install 1 M4 x 12mm safety screw into bottom support frame to further secure the hood FIG F 1 Reinstall mesh fil...

Страница 13: ...s 12 Assemble bottom duct covers together over top duct covers using 3 M3 x 6 screws on each side Bottom duct covers will rest on top of the hood body FIG G 3 13 Insert the 2 thin trim pieces into left and right seams of bottom duct covers 1 on each side FIG G 4 14 Insert the 2 thick trim pieces into left and right seams of top duct covers 1 on each side FIG G 5 Note Because less of the top duct c...

Страница 14: ... IS USED Kit includes charcoal filters charcoal filter bracket and air diverter plate Hood Model Part No Filters in Pkg ZML M90BG BS ZRC 00ML 2 ZML E42BG BS ZRC 00ML 2 1 Purchase recirculating kit per the part number above 2 Secure air diverter plate to top support frame FIG H Run 8 ducting from top of hood and secure to air diverter plate 3 Remove aluminum mesh filters from hood Install charcoal filt...

Страница 15: ...d off and cancel the Delay Off Function 2 Speed Selection Button Fan Speed Decrease Button Press this button to decrease fan speed 6 burst 5 4 3 2 1 If fan is On Speed 1 and this button is pressed fan will power Off Fan Speed Increase Button Press this button to increase fan speed Fan On 1 2 3 4 5 6 burst If hood is Off and this button is pressed fan will turn On Speed 1 Burst Mode This speed leve...

Страница 16: ...ting it is time to replace the charcoal filter Graphic and words will remain illuminated until reset To reset With hood off hold the Button for three seconds after three seconds the Graphic and words replace charcoal filter will turn off and the 120 hour timer will reset Clean Air Indicator Clean Air is a feature that turns the fan on every 4 hours for 10 minutes to remove stagnant air in the kitc...

Страница 17: ...an cotton cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Aluminum Mesh Filters The aluminum mesh filters installed by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are required to be kept clean Remove and clean by hand or in dishwasher on low heat Spray degreasing detergen...

Страница 18: ...brating 1 The motor is not secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation of the hood 4 The switch board or control board is defective 4 Change defective part The motor is working but the lights are not 1 Defective LED bulb 1 Change the LED bulb 2 The LED bulb wire is loose 2 Connect the LED bulb ...

Страница 19: ...Total Max 215W 3 5A Voltage 120V 60Hz Power consumption 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 575 600 625 650 675 700 725 750 Pressure inAq Flow rate CFM Blower fan curve AC input 120V 60Hz Outlet diameter 8 ...

Страница 20: ...inum Mesh Filter 50200043 Optional Accessories Recirculating Kit ZRC 00ML Replacement Charcoal Filter Z0F C002 Duct Cover Extension up to 12 ceiling Z1C 03ML Gray Glass Canopy 90cm ZMG 03GY Gray Glass Canopy 42 ZMG 04GY To order parts visit us online at http store zephyronline com or call us at 1 888 880 8368 ...

Страница 21: ... all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE EXPRESS WARRANTIES IN THE PRECEDING SECTION ARE EXCLUSIVE AND IN LI...

Отзывы: