background image

Important Safety Notice

READ AND SAVE THESE INSTRUCTIONS

2

www.zephyronline.com

WARNING 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. 

WARNING 

TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

a.  Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. 
b.  Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally. 

When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.

CAUTION

For general ventilating use only. Do not use to exhaust hazardous or explosive materials  and vapors.  Take care when using cleaning
agents or detergents. Suitable for use in household cooking area. 

WARNING 

TO REDUCE THE RISK OF RANGE TOP GREASE FIRE: 

a.  Never leave surface units unattended at high settings.  Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly 

on low or medium settings. 

b.  Always turn hood ON when cooking at high heat or when fl aming food   
c.  Clean ventilating fans frequently.  Grease should not be allowed to accumulate on fan or fi lter. 
d.  Use proper pan size.  Always use cookware appropriate for the size of the surface element. 
e.  Keep fan, fi lters and grease laden surfaces clean. 
f.  Use high setting on hood only when necessary. 
g.  Don’t leave hood unattended when cooking. 
h.  Always use cookware and utensils appropriate for the type of and amount of food being prepared. 

WARNING 

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING: 

a.  SMOTHER FLAMES with a close-fi tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. 

If the fl ames do not go out  immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.  

b.  NEVER PICK UP A FLAMING PAN – You may be burned.  
c.  DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d.  Use an extinguisher ONLY if:

1.  You know you have a Class ABC extinguisher, and you already know how to operate it.
2.  The fi re is small and contained in the area where it started.
3.  The fi re department is being called.
4.  You can fi ght the fi re with your back to an exit

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

a.  Installation work and electrical wiring must be done by qualifi ed person(s) in accordance with all applicable codes and standards. 

Including fi re-rated construction.

b.  Suffi cient air is needed for power combustion and exhausting of gases through the fl ue (chimney) of fuel burning equipment to prevent 

back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National
Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and
the local code authorities.

c.  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d.  Ducted fans must always vent to the outdoors.
e.  NEVER place a switch where it can be reached from a tub or shower.
f.  Make sure the power is off before installing, wiring or maintenancing.

Содержание Roma Island ZRM-E36BS

Страница 1: ...Use Care and Installation Guide Model number Serial Number www zephyronline com Roma Island ZRM E36BS ZRM E42BS ZRM E36BS290 ZRM E42BS290 JAN13 0301...

Страница 2: ...www zephyronline com...

Страница 3: ...ght Clearance 6 Ducting Options 7 Hood Speci cations 8 Mounting the Hood 9 10 Ductless Recirculating 11 FEATURES CONTROLS Electronic LED Controls 12 MAINTENANCE Hood and Filter Cleaning 13 Light Bulbs...

Страница 4: ...te for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close tting lid cook...

Страница 5: ...al installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and...

Страница 6: ...6BS ZRM E42BS ZRM E36BS290 ZRM E42BS290 PARTS SUPPLIED HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Hack saw to cut down trim pieces Cable connector if requi...

Страница 7: ...ent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round ro...

Страница 8: ...ose performance and ef ciency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any diffe...

Страница 9: ...ed to the outside unless using the recirculating option Use single wall rigid metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certi ed Silver Tape or Duct Tape...

Страница 10: ...ine com Installation Hood Speci cation CL 35 7 8 41 7 8 14 3 15 16 26 15 16 STANDARD min ducted 28 min recirc 32 max 39 Z1C 01RM EXTENSION min ducted 50 1 2 min recirc 54 1 2 max 79 12 3 1 2 4 1 8 5 6...

Страница 11: ...ord front on the top support frame faces the front of the hood where the controls will be located FIG D The key holes on the top support frame should cover the wood screws previously installed in the...

Страница 12: ...x 1 4 screws FIG D2 9 Assemble Bottom Duct Covers together over top duct covers using the nal 6 M3 x 6 screws 3 screws on each side of the duct cover FIG D3 Bottom Duct Covers should rest on top of t...

Страница 13: ...REQUIRED IF NO DUCTING IS USED Kit includes charcoal lters brackets and air diverter plate Hood Models Part No Filters Brackets in pkg ZRM E36BS ZRC 00RM 2 ZRM E42BS ZRC 01RM 3 1 Purchase recirculatin...

Страница 14: ...If lights are on they will also switch off when this button is pressed These controls feature a memory function that will remember the last setting before being powered off For example If blower is o...

Страница 15: ...on cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Aluminum Mesh Filters The aluminum mesh lters installed by the factory are intended to lter out...

Страница 16: ...ot hot Remove by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are dif cult to turn due to prolonged use rmly attach the included glass suc...

Страница 17: ...stallation of the hood The unit is whistling 1 The lter is not in the correct position 1 Adjust the lters 2 The duct pipe connections are not sealed or connected properly 2 Check the duct pipe connect...

Страница 18: ...16 www zephyronline com Wiring Diagrams...

Страница 19: ...20 Aluminum Mesh Filter each 50200038 Optional Accessories Recirculating Kit ZRM E36BS ZRC 00RM Recirculating Kit ZRM E42BS ZRC 01RM Replacement Charcoal Filter each Z0F C002 Extension Duct Cover Z1C...

Страница 20: ...all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIA...

Страница 21: ...Guide d utilisation d entretien et d installation www zephyronline com Num ro de mod le Num ro de s rie JAN13 0301 Zephyr Corporation Roma Island ZRM E36BS ZRM E42BS ZRM E36BS290 ZRM E42BS290...

Страница 22: ...www zephyronline com...

Страница 23: ...montage 6 Options d installation pour le conduit 7 Sp ci cations de la hotte 8 Montage de la hotte 9 10 Reprise d air sans conduit 11 COMMANDES Commandes lectroniques DEL 12 ENTRETIEN Nettoyage des lt...

Страница 24: ...s surveillance lorsque vous cuisinez h Utilisez toujours une batterie de cuisine et des ustensiles convenant au type et la quantit de nourriture que vous pr parez AVERTISSEMENT POUR R DUIRE LES RISQUE...

Страница 25: ...en quali S assurer que l installation lectrique est ad quate et qu elle respecte le Code national de l lectricit la plus r cente dition du ANSI NFPA 70 ou des normes du CSA C22 1 94 le Code canadien d...

Страница 26: ...Liste du mat riel 4 www zephyronline com...

Страница 27: ...pi x pi embout mural circ registre 30 pi x pi 7 or 10 circ coude 90 15 pi x pi 7 or 10 7 or 10 circ coude 45 9 pi x pi pi pi pi 6 chapeau de toiture circ 30 pi x pi 7 or 10 circ chapeau de toiture 30...

Страница 28: ...pr senter des risques d incendie plus lev s tandis que les hottes install es trop hautes seront dif ciles atteindre et verront leur ef cacit et leur rendement r duits Si elles sont disponibles consult...

Страница 29: ...ppements doivent tre dirig s l ext rieur de la maison moins que l option de reprise d air ne soit utilis e N utilisez que des conduits en m tal pour cloison simple Fixez toutes les pi ces du conduit a...

Страница 30: ...8 www zephyronline com Installation Sp ci cations de la hotte...

Страница 31: ...cadre de xation sup rieur l emplacement d sir au plafond l aide de quatre 4 rondelles et vis bois M4 x 1 1 2 Une vis devrait tre ajout e chaque coin pour xer le cadre de xation au plafond FIG A2 Le ca...

Страница 32: ...r avant d assembler les pi ces de recouvrement de conduit Consultez la page 11 pour de plus amples d tails 8 Fixez les pi ces de recouvrement sup rieures au cadre de xation sup rieur l aide de 2 vis 3...

Страница 33: ...mprend des ltres charbon des supports et un d ecteur d air Mod le de hotte Num ro de pi ce Filtres et supports par paquet ZRM E36BS ZRC 00RM 2 ZRM E42BS ZRC 01RM 3 1 Procurez vous l ensemble de repris...

Страница 34: ...12 www zephyronline com Commandes Commandes lectroniques DEL...

Страница 35: ...et dans le sens du grain N utilisez pas de produits blanchir au chlore ou d agents nettoyants orange Filtres tamis en aluminium Les ltres tamis en aluminium install s par le fabricant ont pour foncti...

Страница 36: ...s d vissant dans le sens contraire des aiguilles d une montre Note les ampoules ne se d vissent pas apr s une rotation de 60 degr s elles s arr tent et tombent de la douille Lorsqu il est dif cile de...

Страница 37: ...appareil vibre 1 Le moteur n est pas bien x en place 1 Fixez solidement le moteur en place 2 La roue du ventilateur est endommag e 2 Remplacez le ventilateur 3 La hotte n est pas bien x e en place 3...

Страница 38: ...16 www zephyronline com Sch ma de c blage...

Страница 39: ...00038 Accessoires optionnels Ensemble de reprise d air ZRM E36BS ZRC 00RM Ensemble de reprise d air ZRM E42BS ZRC 01RM Filtres charbon de remplacement chaque Z0F C002 Ensemble de prolongement de recou...

Страница 40: ...main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE REMPLACER NOTRE GR LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE RECOURS SOUS LA PR SENTE GARANTIE...

Отзывы: