Worn packing.
Remove and replace packing.
Belt slipping.
See BELT TENSION in MACHINE MAINTENANCE.
Improperly sized spray tip or
nozzle.
See MACHINE SPECIFICATIOSN for specified spray
tip or nozzle.
Inlet filter screen is clogged.
Clean inlet filter screen.
Pitted valves.
See VALVE SERVICE in PUMP MAINTENANCE.
Erratic pressure; pump
runs rough
Dirty or worn check valves.
Clean/replace check valves.
Foreign particles in valve
assemblies.
High inlet water temperature.
See temperature in PUMP SPECIFICATIONS.
Excessive vibration
Dirty or worn check valves
See “Dirty or worn check valves.”
Scored plungers
Abrasive material in fluid being
pumped.
Install proper filtration on pump inlet plumbing.
Fitted plungers
Cavitation.
Decrease inlet water temperature and/or increase inlet
water pressure.
Cavitation
High inlet fluid temperature, low
inlet pressure.
Lower inlet fluid temperature and raise inlet fluid
pressure.