English -
46
Repair Instructions
7.22 Handle heating system
The handle heating system comprises the
following:
• Generator
• Power switch
• Heating elements in the rear handle and the
front handle bar.
Troubleshooting
Troubleshooting requires:
• Ammeter
• Ohmmeter
• Coolant
Oxidation of the connectors in the heating
elements in the rear handle and the power switch’s
contact plate is the most common fault.
Troubleshoot as follows:
1
Remove the screw holding the earth cables.
Remove the cover. See Figure 53.
Fig 53
Fig 54
2
Measure the resistance in the whole circuit by
connecting the multimeter to the earth cable and a
properly cleaned cylinder. See Figure 54.
A correct reading with the power switch set to
“OFF” = ∞ Ω.
A correct reading with the power switch set to
“ON” = 3.1 Ω to 4.1 Ω.
Содержание GZ4350
Страница 1: ...Workshop Manual English GZ4350...
Страница 2: ......
Страница 5: ...English 4 Index...
Страница 12: ...11 English 11 12 9 4 Service tools Service tools 4 3 8 1 2 7 10 5 6 13 14 15 16 17...
Страница 15: ...English 14 Service data...
Страница 58: ...57 English Troubleshooting 8 Troubleshooting Contents 8 1 Troubleshooting 58 8 2 Troubleshooting methods 59...
Страница 61: ......
Страница 62: ...www zenoah com 115 96 21 26 3 4 2019...