802253NZ - HydroTap BC, BCHA -AV, AIO, Installation Instructions - Aug 2015 - V2.01
Page 33 of 36
•
Turn ON the water and check for any leaks.
•
Turn the power ON at the GPO and at the side of the undersink unit
•
If fitted, ensure the Booster is turned OFF. (The Booster is commissioned, later, at section 5.4)
•
Familiarise yourself with the operation of the Tap, in preparation for use (See User Guide)
•
Follow the Installation instructions below (and review Section C of the User Guide).
•
After commissioning, the system may be customised by selecting further options in Section G -
Settings, within the User Guide.
1.
Turn the stop cock ON
2.
Press [Start] [Stop] buttons to start and stop the filter flush.
3.
Allow at least 10 litres of water to flush through the filter.
4.
Once the filter flush is finished, Turn the stop cock OFF
then press [Stop] to end filter flush mode.
5.
Press [Next] and the View screen will show the Flow
calibration mode.
6.
Press the [Start] button and the tank will first empty then fill.
Upon completion the actual pulse will be displayed.
7.
Press [Next] for the Boiling Calibration screen.
Have a 10L bucket or similar container (not supplied) at the
ready to hold a quantity of water that will be ejected while the
Filter Flush Mode is in operation. Open the filter access door
on the front of the HydroTap and the filter cartridge will be
exposed. Located to the rear RHS of the cartridge is a flush
line, approx 600mm long and the flush line stop cock. Place
the valve end of the flush line into the 10L bucket or container
(not supplied).
5.2
-
Filter Flush
Section 5
Commissioning
5.3
-
Flow Calibration
NOTE:
For any subsequent fi lter changes or any operational
procedures, please refer to the HydroTap user guide, located
inside the fi lter housing access door.
5.1
-
Select the Language
Initial Commissioning screen
Language selection screen
OPEN
CLOSED
Stop cock
operation