802253NZ - HydroTap BC, BCHA -AV, AIO, Installation Instructions - Aug 2015 - V2.01
Page 31 of 36
Note: to activate the filter, flush at least 10L of water through the filter before connecting to a softener or to a
Booster heater.
Installation Instructions
4.5
Model: All-In-One Vented
Tee piece and
Restrictafl ow
valve (supplied)
External COLD
isolation valve
(Not Supplied)
RED
CLE
A
R
BLUE
BR
A
IDED
POWER
CORD
USB
MAINS
IN
MIXER
OUT
MIXER
IN
BOILING
OUT
BYPASS
IN
VENT BYPASS
OUT
CHILLED
OUT
Booster
HT Mixer
connections
BR
A
IDED
BR
A
IDED
BR
A
IDED
BR
A
IDED
Note:
All
silicon tubes
must be cut to
size. They must
have a constant
fall back to the
unit.
Note:
- Mains hose
length is 750mm
- Plug and Cord
length is 1800mm
Position the under
sink unit close
to the outlet tap,
within reach of
the hose and cord
lengths supplied
Note:
The tube lengths are matched to the pumps performance and therefore CANNOT be lengthened