ip Tudor - Installation & Operating Instructions - 81333 - May 2003

Installation Procedure 

continued

Step Two - Positioning

Over-sink heaters should be installed so that the outlet spout drains to a sink
or basin, and with a clearance of 270 mm beneath the heater to allow for
service access.

Under-sink heaters should be installed a closely as possible to directly below
the outlet tap  with a clearance of 270 mm above the heater.

Step Three - Fastening

It is not necessary to remove the case of the heater during installation.

The heater must be wall mounted with two fixing screws as shown in the
diagram on page 5. Fixing screws must have the strength to support the filled
heater.

The fixing screws are to protrude 4 mm from the wall as shown in the diagram
on page 5 so as to fit into keyhole slots provided on the rear of the heater.

Step Four - Connecting

On over-sink models, the inlet and outlet are located on the base of the heater.

On under-sink models, the inlet and outlet are located on the top of the heater.

All Z

enith

 Tudor water connections are via 15 mm compression fittings and must

be made strictly as shown in the diagrams.

Over-sink models are supplied with a 300 mm open outlet spout, and must
also be fitted with an isolation valve on the cold water side. A valve is not
supplied with the heater and must be supplied and fitted by the installer.

Under-sink models must be installed with approved vented tapware regulating
the incoming water supply which displaces the hot water from the heater so it
discharges through the open vented spout incorporated into the tap mounted
on the basin or sink.

The use of tapware other than approved vented tapware is dangerous.

Each heater is equipped with a 1600 mm power cord and plug and should be
connected to a standard 10 amp power outlet located adjacent to the heater.

Do not turn the power ON until the heater is filled with water and air is purged
from the heater.

Step Five - Commissioning

Fill the heater tank and purge air from the heater by turning the water supply
ON and running water through the heater until it flows smoothly. Turn the water
supply OFF and turn the power supply ON. The heater will then run through its
heating cycle.

During the heating cycle, drips  fall from the delivery spout or tap.

Dripping will cease when the heating cycle is completed and the stored water
temperature has reached the level set by the user.

Model

Weight(kg)

Empty

Full

Five Litre
over-sink

3.5

8.5

Ten Litre
under-sink

  4.0             14.0

Five Litre
over-sink

    3.5               8.5

Ten Litre
under-sink 4.0

14.0

Page 4

Z

enith 

Tudor - Installation & Operating Instructions - 81333 - July - 2004

Содержание 216666666

Страница 1: ...lo vented mixer tap for 21010 21030 99050 Hero vented mixer tap for 21010 21030 Installation Operating Instructions 21600 Zenith Tudor 5 Litre over sink water heater 21620 Zenith Tudor 10 Litre over s...

Страница 2: ...outlet All plumbing connections must be made in accordance with AS3500 The heater is intended only for indoor use and should never be installed outdoors or be exposed to the elements of nature Over s...

Страница 3: ...ible tubes are firmly attached to the base of the tap body 2 Flush water supply pipes thoroughly to remove any silt or fines 3 Fasten the tap body to the sink using the bolt plate system provided 4 Co...

Страница 4: ...must also be fitted with an isolation valve on the cold water side A valve is not supplied with the heater and must be supplied and fitted by the installer Under sink models must be installed with app...

Страница 5: ...erlaod Check power supply Contact Zenith No water No supply Blockage Faulty thermostat Faulty cut out Check water supply Contact Zenith No indicator Faulty LED Faulty connection Contact Zenith Zip Tud...

Страница 6: ...mperature control will maintain stored water temperature over 5 C to prevent freezing and damage to the water heater The same protection does not extend to connecting pipework or fittings Safety Cutou...

Страница 7: ...erse is applicable Attach the thermostat to the plastic upright Reconnect the two electrical terminals It does not matter which way around the connections occur Ensure the remaining capillary coil is...

Страница 8: ...s are payable by the customer other than any mileage or travelling time charges incurred by a Zenith Service Provider or the cost of removal cartage and re installation of any component of the applian...

Отзывы: