Operating Procedures

Water Temperature

Z

enith

 Tudor water heaters are fully automatic, and may be left switched ON

under the control of the variable thermostat.

Nominal operating temperature can be varied from about 30°C to about 80°C.

Temperature should not be set to less than 60°C without due regard to
regulations governing the storage temperature of hot water.

Economy Setting

The economy setting "E" will maintain stored water temperature at
approximately 60°C. At the "E" setting, the temperature control locates into a
set position and a slight resistance will be felt when rotating the temperature
control beyond that setting. This measure is to help ensure that higher
temperatures are only selected deliberately.

Frost Protection

If the heater is located where ambient air temperature could fall below 5°C
when the heater is not in use, the "anti freeze" setting on the temperature
control will maintain stored water temperature over 5°C to prevent freezing
and damage to the water heater.

The same protection does not extend to connecting pipework or fittings.

Safety Cutout

Should the heater over-heat, a manually resettable safety cutout will
automatically turn the heating element OFF. The cutout must be reset by a Z

enith

Service Provider or a licensed electrician. Users should never reset the cutout
without qualified assistance.

Cleaning

Never use strong, corrosive or abrasive cleaning materials. Wipe clean the
outer surfaces with a sponge or soft cloth using a mild soap and water.
Domestic dish washing liquid detergent is most suitable.

ECONOMY

HIGH

OFF

ANTI-

FREEZE

LOW

PART NO DESCRIPTION

Z

90401

element neck ring kit Tudor

Z

90407

fascia kit Tudor undersink

Z

90408

fascia kit Tudor oversink

Z

90415

element kit Tudor 5ltr o/sink

Z

90416

element kit Tudor 10ltr o/sink

Z

90417

element kit Tudor 5ltr u/sink

Z

90418

element kit Tudor 10ltr u/sink

Z

90420

pilot light kit Tudor

Z

90421

thermostat kit Tudor

Z

90423

overload kit Tudor

Spare Parts

Page 6

Z

enith 

Tudor - Installation & Operating Instructions - 81333 - July - 2004

Содержание 216666666

Страница 1: ...lo vented mixer tap for 21010 21030 99050 Hero vented mixer tap for 21010 21030 Installation Operating Instructions 21600 Zenith Tudor 5 Litre over sink water heater 21620 Zenith Tudor 10 Litre over s...

Страница 2: ...outlet All plumbing connections must be made in accordance with AS3500 The heater is intended only for indoor use and should never be installed outdoors or be exposed to the elements of nature Over s...

Страница 3: ...ible tubes are firmly attached to the base of the tap body 2 Flush water supply pipes thoroughly to remove any silt or fines 3 Fasten the tap body to the sink using the bolt plate system provided 4 Co...

Страница 4: ...must also be fitted with an isolation valve on the cold water side A valve is not supplied with the heater and must be supplied and fitted by the installer Under sink models must be installed with app...

Страница 5: ...erlaod Check power supply Contact Zenith No water No supply Blockage Faulty thermostat Faulty cut out Check water supply Contact Zenith No indicator Faulty LED Faulty connection Contact Zenith Zip Tud...

Страница 6: ...mperature control will maintain stored water temperature over 5 C to prevent freezing and damage to the water heater The same protection does not extend to connecting pipework or fittings Safety Cutou...

Страница 7: ...erse is applicable Attach the thermostat to the plastic upright Reconnect the two electrical terminals It does not matter which way around the connections occur Ensure the remaining capillary coil is...