background image

Z

enith

 Tudor

Single point open outlet (vented) water heaters

p Tud over-sink water heater
21

6666666

Zip Tudor 5 Litre under-sink water heater

21

6666666666

utor 10 Litre under-sink water heate

99032

Telescopic Spout accessory for 21000 / 21020

9903

9999999

4 Mono vented mixer tap fo

66

r 21010 / 21030

9

1

9

111

0

88

lo vented mixer tap for 21010 / 21030

99050

Hero vented mixer tap for 21010 / 21030

ä

Installation & Operating Instructions

21

6

00

         Z

enith

 Tudor 5 Litre over-sink water heater

21

6

20 

        Z

enith

 Tudor 10 Litre over-sink water heater

21

6

10

         Z

enith

 Tudor 5 Litre under-sink water heater

21

6

30

         Z

enith

 Tu

d

or 10 Litre under-sink water heater

99032

Telescopic Spout accessory for 21

6

00 / 21

6

20

99

0

7

9         M

ono vented mixer tap for 21

6

10 / 21

6

30

990

80         S

olo vented mixer tap for 21

6

10 / 21

6

30

990

81         H

ero vented mixer tap for 21

6

10 / 21

6

30

Содержание 216666666

Страница 1: ...lo vented mixer tap for 21010 21030 99050 Hero vented mixer tap for 21010 21030 Installation Operating Instructions 21600 Zenith Tudor 5 Litre over sink water heater 21620 Zenith Tudor 10 Litre over s...

Страница 2: ...outlet All plumbing connections must be made in accordance with AS3500 The heater is intended only for indoor use and should never be installed outdoors or be exposed to the elements of nature Over s...

Страница 3: ...ible tubes are firmly attached to the base of the tap body 2 Flush water supply pipes thoroughly to remove any silt or fines 3 Fasten the tap body to the sink using the bolt plate system provided 4 Co...

Страница 4: ...must also be fitted with an isolation valve on the cold water side A valve is not supplied with the heater and must be supplied and fitted by the installer Under sink models must be installed with app...

Страница 5: ...erlaod Check power supply Contact Zenith No water No supply Blockage Faulty thermostat Faulty cut out Check water supply Contact Zenith No indicator Faulty LED Faulty connection Contact Zenith Zip Tud...

Страница 6: ...mperature control will maintain stored water temperature over 5 C to prevent freezing and damage to the water heater The same protection does not extend to connecting pipework or fittings Safety Cutou...

Страница 7: ...erse is applicable Attach the thermostat to the plastic upright Reconnect the two electrical terminals It does not matter which way around the connections occur Ensure the remaining capillary coil is...

Страница 8: ...s are payable by the customer other than any mileage or travelling time charges incurred by a Zenith Service Provider or the cost of removal cartage and re installation of any component of the applian...

Отзывы: