19
6. MINOR PROBLEMS: CAUSES AND SOLUTIONS
FAULTS POSSIBLE
CAUSE
SOLUTION
no voltage
check the power supply line
automatic switch tripped
reset the switch and establish the cause
impeller jammed
establish the cause of the trouble and remove it
motor does not turn
thermal protection cut in
resets automatically (not on -EX versions)
check valve jammed
clean the valve and check its operation
motor functions normally but no water
is pumped
blocked pipeline
identify the obstruction and remove it
impeller, valve or pipelines obstructed
identify the obstruction and remove it
liquid level too low
turn the pump off immediately
incorrect supply voltage
match the voltage to the values indicated on the
data plate
pump has reduced flow rate
wrong direction of rotation (three phase motor)
invert any two phases
impeller jammed
identify the cause of the trouble and remove it
thermal protector has cut in
temperature of liquid too high
contact your nearest Zenit dealer
7. DISPOSING OF MOTOR PUMPS
In the event that is not considered economically viable to repair a worn or damaged motor pump, the motor pump and motor must be disposed of in
full compliance with local regulations.
To dispose of a motor pump proceed as follows:
- remove any oil in the chamber and dispose of in a specialised collection centre;
- separate the parts in plastic and rubber and dispose of in a specialised collection centre;
- arrange for the break-up of the metal parts.
Do not dispose of any motor pump component in the environment.
8. ELECTRICAL CONNECTION
8.1 SINGLE PHASE ELECTRIC MOTOR CONNECTION
Connect the yellow-green lead to earth and supply the leads on the motor pump fas follows: BLACK lead to a line connector; blue lead to the other
line connector or to capacitor\circuit breaker; BROWN lead to the other capacitor\circuit breaker connector.
SINGLE-PHASE electrical connection fig. 3-4-5 on page 84.
8.2 THREE PHASE ELECTRICAL CONNECTION
Connect the yellow-green lead to earth and supply the motor pump output leads. If the motor pump has 3 leads they must be connected to a three
phase line with voltage and frequency equal to that indicated on the data plate, or to a control panel with devices to reduce the initial current. If the
motor pump has 6 leads they must be connected to a control panel with a Y/delta switching device. If the connection is made directly to the delta the
supply voltage is the lower of those indicated on the data plate; if the connection is made to the Y the voltage is the higher of those indicated. The
supply leads are marked as follows:
- 3 leads U – V – W;
- 6 leads U1 – U2 – V1 – V2 – W1 – W2;
THREE-PHASE electrical connection fig. 6-7-8-9 on page 84-85.
8.3 THERMAL PROBES
Thermal protection is incorporated in the motors and resets automatically in the single phase versions and in the three phase versions equipped
with thermistors or remote control switches. In the three phase versions without remote control switches the thermal protection, where present, is
connected to the motor pump outlet leads labelled T. The thermal protection must be connected to the corresponding terminal on the control panel.
8.4 CONDUCTIVITY PROBES
Where present the conductivity probe is inserted in the oil chamber and connected to the motor pump output lead labelled S. The probe must be
connected to the corresponding terminal on the control panel.