TECHNICAL SPECIFICATION & RATINGS
Ensure to select the appropriate controller model to according to the PV modules, motor and load requirements.
Ensure to number of PV Modules per string do not exceed the ECODRIVE’s maximum voltage rating under all conditions.
Electrical Specifications:
The following applies to the 480V model (suitable for 3 Phase motors)
PV DC Input Voltage:
Maximum 800VDC
(Must ensure that Voc at lowest operating temperature does not exceed this voltage)
Auxiliary AC Input Voltage: 380 - 480Vac 3 Phase or 1 phase
(-15%, +10%)
Nominal MPP Voltage:
407-727VDC
Output Voltage:
0-480VAC 3 Phase
Output Frequency:
0-200Hz (maximum speed subject to DC bus voltage & solar energy available)
V/Hz:
Adjustable
For all other voltages contact Zener.
Input / Output Current:
Model
Continuous
Output Current
(Amps)
Nominal Motor
Nameplate
Power (kW)
40°C / 50°C
PV DC Input current
(A RMS max.)
Auxiliary AC Input
Current with DC bus
Choke fitted
(A RMS max.)
40°C
50°C
Continuous Intermittent
8E001XX
2.0
2.0
0.75 / 0.75
2.4
3.2
1.9
8E003XX
3.6
3.0
1.5 / 1.1
4.4
5.7
5.2
8E005XX
5.0
4.1
2.2 / 1.5
6.1
7.9
6.9
8E007XX
7.2
6.0
3.0 / 2.2
8.7
11.4
9.7
8E011XX
10.8
9.0
5.5 / 4.0
13.1
17.1
13.6
8E016XX
16.0
13.2
7.5 / 5.5
18.1
23.5
17.8
8E023XX
22.5
18.8
11.0 / 7.5
27.3
35.5
27.7
8E030XX
30.1
25.0
15.0 / 11.0
36.6
47.5
35.4
8E040XX
40.3
33.8
22.0 / 15.0
49.0
63.7
44.4
8E057XX
57.0
46.0
30.0 / 22.0
69.2
84.8
64.2
8E082XX
82.0
69.1
45.0 / 37.0
100
125
89.1
8E109XX
109.0
91.3
55.0 / 45.0
132
166
123
8E140XX
140.0
118.9
75.0 / 55.0
170
213
153
8E170XX
170.0
141.3
90.0 / 75.0
207
227
183
Contact Zener for sizes above this for a customised solution, up to 490Amps
Refer to instruction manual IM00124 for more details on ratings, in particular for standard 3phase AC operation and
recommended circuit protection.
2
For single phase operation a DC bus choke must be fitted and a derating applied. Contact Zener for assistance.
3
The output voltage cannot be higher than the AC input voltage or 70% of the DC input.
4
Always select the ECODRIVE on motor full load current not power.