ZENER VARIDRIVE SOLUTIONS
ZENER ECODRIVE® 8000
IM00130
P a g e
| 44
20/07/2018 3:59 PM
Application
<Tank Solar>
C00 PERFORMANCE
C03 RAMP
C030 ACCEL TIME
10.0Secs
ADDITIONAL SETTINGS
This manual is intended to simplify the setup process for Solar Operation by providing ‘application specific’ menus. The ECODRIVE
has many more features, parameters and functionality which can be accessed in other menus to suit individual requirements. For
assistance with other configurations contact Zener or refer to the ZENER 8000 Instruction manual.
Some settings that may be required for pumping & solar applications include:
Dual Ramp:
A dual ramp configuration is available to have different acceleration rates above or below the minimum speed setting. When
Dual Ramp is enabled, C032 S TIME specifies the acceleration & deceleration rate below the minimum speed. The C030 ACCEL
TIME and C031 DECEL TIME relates to the acceleration & deceleration rate above the minimum speed.
The settings for Dual Ramp can be found in the same menu location as Acceleration Ramp. Follow the procedure below to
access & modify the ramp times.
Acceleration Ramp:
Some pumps require a fast acceleration time (1 or 3 seconds to reach 30Hz). It is recommended to consult the pump/motor
manufacturer to confirm requirements or contact Zener to discuss.
To change the Acceleration time.
To edit
To adjust, then
to ENTER & EXIT
Minimum Hz (Speed) Setting
C032 S TIME
C030 ACCEL TIME
C031 DECEL TIME
Slope = B03 Motor Hz/ C032 S TIME
Slope = B03 Motor Hz/ C031 DECEL TIME
Slope = B03 Motor Hz/ C031 DECEL TIME
ESC
Default Setting:
Tank Fill: < Minimum speed = 0.5 seconds (C032)
>
Minimum speed = 10 seconds (C030)
Pressure: < Minimum speed = 0.5 seconds (C032)
>
Minimum speed = 2 seconds (C030)
Содержание ECODRIVE 8000
Страница 29: ...ZENER VARIDRIVE SOLUTIONS ZENER ECODRIVE 8000 IM00130 P a g e 27 20 07 2018 3 59 PM Intentionally Blank...
Страница 31: ...ZENER VARIDRIVE SOLUTIONS ZENER ECODRIVE 8000 IM00130 P a g e 29 20 07 2018 3 59 PM Intentionally Blank...
Страница 37: ...ZENER VARIDRIVE SOLUTIONS ZENER ECODRIVE 8000 IM00130 P a g e 35 20 07 2018 3 59 PM Intentionally Blank...