INSTALLATION & WIRING
REMINDER: This equipment must be installed by qualified electrical personnel with the appropriate accreditations. The
equipment operates from 800VDC which requires special consideration when installing and operating. Refer to all warnings
located at the front of this manual. This manual should be read in conjunction with the ZENER 8000 instruction manual and
all applicable standards and regulations.
PLEASE READ ALL WARNINGS IN SECTION 1 BEFORE PROCEEDING.
Section 1 contains critical safety warnings that relate to the installation of the equipment in particular earthing
requirements.
Mounting location
In general the ECODRIVE should be mounted as close to the motor as practical, consistent with other requirements. This is
not an absolute requirement, but does provide some advantages.
The ECODRIVE must be mounted to a wall or internal mounting plate of an enclosure. Ensure that the full weight of the
ECODRIVE can be supported.
The equipment must be protected from direct sunlight and installed in a location suited to its enclosure type. If installed in an
enclosure, adequate ventilation is required and temperature rise within the enclosure considered.
The ECODRIVE must be mounted with clearance around the vents and the enclosure to allow for sufficient airflow for the
enclosure to dissipate heat. The following clearances should apply.
CHA Allow 50mm above, below and either side of the enclosure
CHB Allow 75mm above, below and either side of the enclosure
CHC Allow 100 above, below and either side of the enclosure
•
Do not drill holes in the enclosure except in the gland plate provided.
•
Remove the gland plate before drilling holes.
•
Do not allow metal shavings or other conductive material to enter the enclosure or damage may result.
•
The location & environment should provide for safe access and working conditions for service personnel. Do not
mount the equipment in a ‘Confined Space’
.
For all other auxiliary equipment such as PV modules, transducers, diodes refer to the manufacturer’s instructions.
5
Confined spaces are generally defined in occupational health and Safety regulations to mean spaces where special precautions
are necessary to ensure a safe breathing atmosphere, or there is limited access for escape/rescue in case of an emergency.