Operating Manual ZEMMLER MULTI SCREEN MS 1600
Service and maintenance
MS1600.153.19
Page
54
11.7.1
Outer wire screens
Remove wire screens:
1. Open the right side door of the trommel in the direction of travel.
2. Place the clamping station ot the trommel at the mounting height in inching mode
and loosen the screws.
3. Loosen both ends of the wire screen with help of the mounting lever out of the
clamping station.
4. Carefully pull the screen out of the machine.
Apply wire screens:
1. Position clamping station of the trommel by remote control in inching mode just
above mounting height.
2. Hook the end of the wire screen without screws into clamping station.
3. Rotate trommel by hand until the pad is completely wrapped around the trommel.
4. Put ends into clamping station with mounting lever and use the screws to tighten the
wire screen pad. (see figure 11.2)
fig. 11-2: Clamping station of the wire screen pads