44
7.1.14
No Isolation guard active
Full message:
No ISO, please / Contact Zeliox (orange)
Means:
No isolation guard active. Contact Zeliox ASAP
Action:
Error message and activities are stopped (no output
and input)
7.1.15
No DC/DC converter active
Full message:
NO DC/DC / Converter (orange)
Means:
It is not possible to charge the Zeliox via de attenuator
Action:
Error message and activities are stopped (no output
and input)
7.1.16 Internal battery is too cold
Full message:
Bat-cold, No power output (orange)
Means:
The internal battery is too cold for operation.
Action:
Error message and activities are stopped (no output
and input)
7.1.17 Internal battery is too hot
Full message:
Bat-hot, No power output (orange)
Means:
The internal battery is too hot for operation.
Action:
Error message and activities are stopped (no output
and input)
7.1.18 Power limit reached
Full message:
Power limit / reached (1800VA) (orange). Two 2000Hz
beeps can be heard.
Means:
The output power exceeded 1800VA.
Action:
Error message and activities are stopped (no output
and input). User has to remove load and restart Zeliox
7.1.19 Case open warning
Full message:
Case open / Close case (white). One 1000Hz beep is
generated
Means:
The System detected an open case.
Action:
Warning Only
7.1.20 Air pressure warning
Full message:
Air pressure! / Out of spec (white).
Means:
Ambient air pressure is too high.
Action:
Warning Only
Содержание ZEL16-1,2-EU
Страница 1: ...User Installation Manual Zeliox Compact ENGLISH...
Страница 6: ...6 User Manual Zeliox Compact ENGLISH...
Страница 25: ...25 Installation Manual Zeliox Compact ENGLISH...
Страница 46: ...46 Notes...
Страница 47: ...47 Notes...
Страница 48: ...48 Zeliox BV Spaarpot 13 5667 KV Geldrop The Netherlands www zeliox com...