21
8. Sensors
8.1 Explanation of sensors
8.1.1 Temperature sensors
The Zeliox Compact contains several temperature sensors placed in
internal crucial places:
• Mainboard sensor – This sensor measures the temperature of the CPU
board. If the temperature is too high, the Zeliox Compact switches off.
• CPU sensor- This on-chip sensor measures the temperature of the CPU
chip. If the temperature is too high, the Zeliox Compact switches off.
• Main battery temperature sensors (2x) – These sensors measure the
temperature of the main battery. If the temperature is too high, the
charging process will stop to prevent damage (55°C), the charging
process will also stop at a temperature below 5°C. At 0°C, the discharge
of the main battery also stops.
• Fan controller sensor – this sensor is connected, but is used passively.
8.1.2 Humidity sensor
This humidity sensor measures the humidity in the Zeliox Compact.
The CPU calculates the dew point based on the temperature. The Zeliox
Compact switches off when the dew point temperature is reached to
prevent damage to the electronics.
8.1.3 Pressure sensor
This sensor estimates the current height at which the Zeliox Comact is
located. The Zeliox Compact turns off if the air pressure is too low, as it
may be unsafe to charge the battery.
8.1.4
Accelerometer and magnetometer (6-axes)
The accelerometer keeps track of whether the Zeliox Compact has been
involved in a high-energetic collision. In that case, integrity and therefore
safety of the Zeliox Compact can no longer be guaranteed, so the Zeliox
Compact will shut down completely and it needs to be checked by the
experts of Zeliox®. It is not allowed to turn the Zeliox Compact upside down
or on its back. This sensor also checks whether this situation has occurred.
8.1.5 Case open sensor
It is not allowed to open the Zeliox Compact by unauthorized personnel, the
Zeliox Compact contains dangerously high voltages. This sensor checks
whether the housing of the Zeliox has been opened. If the Zeliox is opened,
the Zeliox Compact will no longer function and has to be reset at a cost by
the experts of Zeliox®.
Содержание ZEL16-1,2-EU
Страница 1: ...User Installation Manual Zeliox Compact ENGLISH...
Страница 6: ...6 User Manual Zeliox Compact ENGLISH...
Страница 25: ...25 Installation Manual Zeliox Compact ENGLISH...
Страница 46: ...46 Notes...
Страница 47: ...47 Notes...
Страница 48: ...48 Zeliox BV Spaarpot 13 5667 KV Geldrop The Netherlands www zeliox com...