19
7.1.4 Power safety mode
The power safety mode starts when the main battery reaches a voltage
below 9.8 volts. The Zeliox Compact will go completely off.
The Zeliox Compact control unit will operate entirely on a back-up battery.
Power consumption is minimized and the Zeliox Compact will give a
warning for about 7 days via the LED in the on/off switch. This LED will
then light up briefly every 30 seconds.
The Zeliox Compact can be restarted by the following actions:
• Connecting to the mains
• Turn on contact (vehicle/vessel)
The main battery will be recharged after the Zeliox Compact is connected
to the mains or the contact is turned on. The Zeliox Compact will switch
off again after 10 seconds if the ignition is turned on, but the alternator
does not charge.
If the backup battery runs out, please contact Zeliox.
7.1.5 Charging mode
The Zeliox Compact is connected to the mains or charged by the alternator.
Charging will remain active until the battery has reached a voltage of 14.4
Volts. The charger places a higher voltage on the main battery due to the
alternator. The battery level indicator will not indicate the nominal voltage
of the main battery but will be based on the charging voltage.
7.2
Battery behaviour
7.2.1 Introduction
This chapter describes the behaviour of a LiFePO4 battery that is of
interest to the end user.
7.2.2 Battery characteristics
The main battery in the Zeliox Compact is of the type LiFePO4. This
lightweight battery has some good features such as high energy density.
A theoretical ideal voltage source has a number of characteristics:
• Constant voltage
• Internal resistance of 0 ohms
• Unlimited power
• Temperature independent
Содержание ZEL16-1,2-EU
Страница 1: ...User Installation Manual Zeliox Compact ENGLISH...
Страница 6: ...6 User Manual Zeliox Compact ENGLISH...
Страница 25: ...25 Installation Manual Zeliox Compact ENGLISH...
Страница 46: ...46 Notes...
Страница 47: ...47 Notes...
Страница 48: ...48 Zeliox BV Spaarpot 13 5667 KV Geldrop The Netherlands www zeliox com...