background image

User & Installation 

Manual

Zeliox Compact

ENGLISH

Содержание ZEL16-1,2-EU

Страница 1: ...User Installation Manual Zeliox Compact ENGLISH...

Страница 2: ...Potective devices 22 10 Safety 23 11 Trouble shooting 24 1 Installation 26 2 Rear connections 27 3 Engine run signal 30 4 APPENDIX II MSDS Material Safety Data Sheet 32 5 Glossary and abbreviations 39...

Страница 3: ...1 20 EU 1600Watt 1 2kWh shore power Dimensions and weight Dimensions 420 x 190 x 370 mm l x h x d Weight ZEL16 1 20 EU 23 Kg ZEL16 1 20 EV 22 Kg Product identification Zeliox Compact lithium ion batte...

Страница 4: ...y be used by qualified and trained users WARNING Check that the Zeliox Compact is not damaged during transport If damaged contact the supplier Disable the Zeliox Compact completely on off switch and c...

Страница 5: ...of explosion Decomposition by fire or heat with formation of toxic and stinging gases Combustion gases that are highly irritating to the eyes and respiratory organs General measures to be taken by th...

Страница 6: ...6 User Manual Zeliox Compact ENGLISH...

Страница 7: ...ashboard connector has the same function one to one LED statuses Constantly on the Zeliox Compact is on Constant flashing The Zeliox Compact charges via the mains It is a warning to the end user that...

Страница 8: ...onnect your electrical devices Use a extension cord if multiple devices need to be used at the same time Make sure that the total power does not exceed the Zeliox Compact specification Do not use a ex...

Страница 9: ...us voltages in the Zeliox Compact 4 Isolation monitor status Indicates the status of the isolation monitor 5 Zeliox settings statuses Indicates which settings are active 6 Various operational statuses...

Страница 10: ...spheres displays the following statuses D Lights up green when DC DC converter vehicle charging is active B Lights up green when backup battery is charging F Lights up green if Main battery is full 2...

Страница 11: ...e set via the main screen of the Zeliox Compact software wise this in contrast to the D boxes which must be adjusted with a set potentiometer 3 1 2 Required materials The following materials are neede...

Страница 12: ...requested this is the value at which the Zeliox Compact stops charging again The value to be entered is V battery 0 5 For example if V battery 12 7V then the value to be entered is 127 period is added...

Страница 13: ...is mode compared to fixed dimming 4 1 4 Set time and date The Zeliox is set at the right time from the factory The date has the following format DD MM 20YY 4 1 5 Mute The buzzer of the Zeliox Compact...

Страница 14: ...start The 230V output is active when this option is set on by default 4 1 10 Marquee status With this setting the marquee can be switched on of in the area above the Zeliox logo additional informatio...

Страница 15: ...mpact is not connected to the mains and the 230V inverter is switched on 230V will be applied to both front schuko socket and the back fixed connection for users This output is immediately available b...

Страница 16: ...prevents the inverter from being left on unnecessarily when the voltage drops The following voltages appear directly on the respective outputs 230V at the front and rear 5V front USB On the display t...

Страница 17: ...off switch will start flashing to indicate that charging is active 6 1 2 Operating status on with charging from alternator switch on and off First switch on the Zeliox Compact via on off switch then s...

Страница 18: ...nal main battery The voltage of the internal battery in this mode is between 10 2 and 14 4 volt when reaching a voltage of 10 2 volts the Zeliox Compact will switch to battery protection mode 7 1 3 Ba...

Страница 19: ...t the alternator does not charge If the backup battery runs out please contact Zeliox 7 1 5 Charging mode The Zeliox Compact is connected to the mains or charged by the alternator Charging will remain...

Страница 20: ...ttery cannot supply the requested energy This does not mean that the battery is empty but it will recover afterwards 7 2 6 Battery protection The ambient temperature affects the behaviour of the batte...

Страница 21: ...The Zeliox Compact switches off when the dew point temperature is reached to prevent damage to the electronics 8 1 3 Pressure sensor This sensor estimates the current height at which the Zeliox Comac...

Страница 22: ...shortcomings of an earth leakage circuit breaker in this situation an insulation monitor has been installed in the Zeliox Compact 9 1 3 Isolation monitor In some cases the earth leak switch cannot fun...

Страница 23: ...compact 10 1 1 Summary The Zeliox Compact is equipped with various sensors to make the operation of the Zeliox Compact as safe as possible However the end user must use the device within the specific...

Страница 24: ...24 11 Trouble shooting 11 1 Zeliox App Download the Zeliox App www zeliox com Apple Store iOS Google Play Android...

Страница 25: ...25 Installation Manual Zeliox Compact ENGLISH...

Страница 26: ...eparation The installation must be carried out by professional installers only Check the site www zeliox com for the installation instructions for various systems such as Aluca Bott Sortimo etc 1 2 Ma...

Страница 27: ...placed The connector has a lock to prevent the cable from accidentally unplugging The voltage on this connector is around 230V 50Hz and is purely sinusoidal resulting in less electromagnetic radiatio...

Страница 28: ...nector type IEC C19 a charging cable is included as standard 2 1 5 12V in connector The Zeliox Compact can be connected to a vehicle by this connector The input voltage is between 10 and 15V A built i...

Страница 29: ...hite 1 Red 2 Brown 2 Green 3 Green 3 Blue 4 Yellow 4 Yellow 5 Grey 5 Black 6 Pink optional 7 Blue optional 8 Red optional 2 1 9 Solar Power in optional A solar panel can be connected to the Zeliox Com...

Страница 30: ...e set via the main screen of the Zeliox Compact software wise this in contrast to the D boxes which must be adjusted with a set potentiometer 3 1 2 Required materials The following materials are neede...

Страница 31: ...requested this is the value at which the Zeliox Compact stops charging again The value to be entered is V battery 0 5 For example if V battery 12 7V then the value to be entered is 127 period is added...

Страница 32: ...er means of identification DC to AC Sinewave inverter Lithium ion battery Recommended use This lithium ion battery powered inverter can be used everywhere Restrictions on use Do not overheat do not us...

Страница 33: ...IRST AID MEASURES The product contains organic electrolyte In case of electrolyte leakage from the battery actions described below are required Inhalation Remove to fresh air immediately Take to a med...

Страница 34: ...roduct Following cell overheating due to external source or due to improper use electrolyte leakage or battery container rupture may occur and release inner component material to the environment Eye c...

Страница 35: ...batteries of different types and brands Do not mix new and used batteries Keep batteries in original housing The Zeliox must be fully charged before storing it for a longer period of time Check every...

Страница 36: ...ith plastic front Specific Energy 1 20 kWh Voltage Input 12V output 5V 12V 230V Current Limit At 5V 2A at 12V 20A at 230V 16A Weight 23 Kg EU 1600W 1 20kWh 22 Kg EV 1600W 1 20kWh SECTION 10 STABILITY...

Страница 37: ...of electrolyte solution causes tissue damage to throat and gastro respiratory tract Contents of a leaking or ruptured battery can cause respiratory tract mucus membrane Irritation and oedema SECTION 1...

Страница 38: ...ations which vary from country to country In most countries the trashing of used batteries is forbidden and the end users are invited to dispose them properly eventually through not for profit organiz...

Страница 39: ...Lithium iron phosphate battery GPS Global Positioning System satellite navigation IEC International Electrotechnical Commission an international standardization committee Resistive Touch screen techn...

Страница 40: ...inously 1300W AC output power 3 minutes 2300W AC output power 10 minutes 1600W AC output power peak 10 sec 2500W Operation time 230V 250W 25 C 4h Operation time 230V 500W 25 C 2h Operation time 230V 1...

Страница 41: ...h x d Shore power safety system Auto detect Shore Power shore power must have working earth safety Stand by mode safety auto detect inactivity and auto wake up Low battery warning light and sound warn...

Страница 42: ...continue 7 1 4 Voltage reference error Full message VREF error Contact Zeliox orange Means The 12V voltage domain is not available Action Error message and continue 7 1 5 FAN error Full message FAN er...

Страница 43: ...ssage and Zeliox will continue 7 1 11 Battery protection Mode Full message Bat Protection on Inverter 12V Off orange Means This is the latest message the user will get before the Zeliox will switch of...

Страница 44: ...ties are stopped no output and input 7 1 17 Internal battery is too hot Full message Bat hot No power output orange Means The internal battery is too hot for operation Action Error message and activit...

Страница 45: ...celeration too high Full message Acceleration Out of spec white Means Vehicle acceleration too high Action Warning Only 7 1 24 Contact is on message Full message Contact is on Touch inhibited white Me...

Страница 46: ...46 Notes...

Страница 47: ...47 Notes...

Страница 48: ...48 Zeliox BV Spaarpot 13 5667 KV Geldrop The Netherlands www zeliox com...

Отзывы: