Page 24
W3
Error lamp
Indicates an error. This indicator has always the same
status as the red status LED (7) on the measuring head.
W4
Gloss value
alarm
Indicates that the gloss value is out of range. This
indicator has the same status as the output "GLOSS
VALUE ALARM" on the connector J2 Pin 5 of the
measuring head. The gloss range can be set in the
Settings page of the web interface tool.
W5
Gloss value
Displays the actual gloss value. This value is updated
once a second.
W6
Maximal value
Displays the maximal value of the 100 single
measurements that were used to calculate the gloss
value.
W7
Minimal value
Displays the minimum value of the 100 single
measurements that were used to calculate the gloss
value.
W8
Standard
deviation
Displays the standard deviation of the 100 single
measurements that were used to calculate the gloss
value.
W9
Time
Indicates the time of the measurement.
W10 Gloss value
graph
The graph shows the gloss value (y axis) over time
(x axis).
W11 Graph settings
These adjustment tools can be used to modify the
display mode of the graph.
W12 Geometry
selection
Selection of the active geometry.