Do not switch off the ventilation unless for service 

or when instructed so by the authorities.

Daily usage of the ventilation 

unit

Ventilation is controlled with a simple and easy to 
use touch screen, that has functions based on actual 
operating conditions. The modes available in the 
panel cover all your home ventilation needs. Selecting 
a function changes the ventilation unit operations 
accordingly. The installing technician configures all the 
mode parameters in accordence to the ventilation plan 
when the ventilation unit is commissioned.

Operating modes of the unit

• 

At home 

 (when at home)

• 

Away

 (when not at home)

• 

Overpressure

 (when lighting a fireplace)

• 

Boosting

 (when additional ventilation is needed)

• 

Silent

* (when ventilation needs to be as silent as 

possible)

• 

Max. heating / Max. cooling

* To be activated separately

When at home

When at home, the ventilation mode should be 

At home

.

Check that the central circle on the control panel main 
page has the status “At home”. If it is not so, change it by 
doing the following:

1.  Tap  the green circle in the 
middle of the main page of the 
control panel. 

Choose operating mode

 window 

opens.
2.  Tap the 

At home

 icon. 

Ventilation system is adapting to 
new conditions.

When away

If you are going on a trip, for 
example, or spending time 
away from the building, you 
can configure the ventilation 
accordingly.

1.  Tap the green circle in the 
middle of the main page of the 
control panel.  

Choose operating mode

 window 

opens.
2.  Tap the 

Away

 icon. 

The ventilation system adapts to using less energy when 
you are away.

This function can be timed to switch on when you are not 
usually at home, e.g. during working hours.

In the section 

I want the ventilation system to 

automatically follow my schedule

 there are more 

information about configuring the ventilation system.

If the ventilation unit is used in business premises 

or in a public space, its operating mode might be 

Office.  When the ventilation is operating normally, 

the center circle of the control panel main page 

displays the At office symbol.

FOR INFORMATION

WARNING

Содержание Svea eAir

Страница 1: ...Operating and maintenance instructions for the ventilation unit Svea eAir...

Страница 2: ...t Zehnder Oy 2019 Luvaton kopiointi ja levitys on kielletty Otill ten kopiering och distribution r f rbjuden Uautorisert kopiering og distribuering er forbudt Unauthorised copying and distribution is...

Страница 3: ...e ventilation to follow my schedule automatically 10 How can I save money and energy and advance the healthiness of my living environment 10 What other properties does the ventilation unit have 11 Wha...

Страница 4: ...used by persons including children with reduced physical sensory or mental capacity or without sufficient experience or knowledge unless a person responsible for their safety is supervising and advis...

Страница 5: ...the reason for the malfunction before restarting the unit When you have switched off the power to the unit wait for two 2 minutes before starting the maintenance work Even though the power is switched...

Страница 6: ...leaning the heat exchanger can be found in the Maintenance section If you encounter issues with using the ventilation unit check for answers in the Troubleshooting table at the end of this manual Alwa...

Страница 7: ...eases the heat energy into the supply air when rotating with an efficiency of over 80 How is the ventilation unit used When ventilation is carefully designed and installed you do not have to do anythi...

Страница 8: ...ntrol panel main page has the status At home If it is not so change it by doing the following 1 Tap the green circle in the middle of the main page of the control panel Choose operating mode window op...

Страница 9: ...or putting the children to bed you can switch on the Silent mode You must activate the Silent mode before it can be used for the first time Activating Silent mode 1 Tap the upward arrow on the main pa...

Страница 10: ...ogrammable functions 5 Tap the function you want The function setting window opens 6 Set the start and end times for the function 7 Tap the OK button A window listing the time programs displays and th...

Страница 11: ...emely cold conditions and when indoor air is very humid e g after using the shower and when drying laundry If you are suspecting that the ventilation system settings need to be updated contact the sys...

Страница 12: ...ther values are not editable Menu Description of change Usage mode settings Setting the boost time in the Manual boost settings Setting the overpressure time in the Manual overpressure settings Activa...

Страница 13: ...warm If the air flowing from the ventilation is too warm 1 Tap the minus symbol on the main page of the control panel The temperature reading on the panel changes and the ventilation system begins to...

Страница 14: ...ot working If controlling the ventilation unit with the control panel is not working check that the control panel battery is not run out If the battery is empty recharge it by placing the control pane...

Страница 15: ...m of the screen and then tap the Alarms icon 2 Alarms menu opens and the new alarm is shown first in the list At first glance you can see which alarm was sent when the alarm was sent If you need more...

Страница 16: ...intenance Sufficient maintenance usually covers the following tasks changing filters cleaning the heat exchanger when sweeping the ventilation ductwork cleaning the fans when sweeping the ventilation...

Страница 17: ...17 Operating and maintenance instructions for the ventilation unit Changing filters 2 3 4 1 ISO ePM1 F7 ISO ePM10 M5...

Страница 18: ...e unit after cleaning Heat exchanger Inspecting Before opening the service hatch always make sure that the unit s supply voltage is switched off DANGER 1 Check the condition of the heat exchanger visu...

Страница 19: ...rew the six screws on the heat exchanger maintenance hatch lid at the front side of the heat exchanger 6 Inspect the belt wheel to make sure it is undamaged in its place and rotating properly 7 Clean...

Страница 20: ...e that the belt is in its place and everything looks fine 16 Vacuum clean the heat exchanger casing Rotate the heat exchanger when you are vacuuming to be sure to clean everywhere 17 Close the mainten...

Страница 21: ...s located in the electric box of the unit Contact service HRW pulley has separated from the shaft Check from the HRW round opening if the shaft is rotating empty and the pulley is in its place Contact...

Страница 22: ...air ducts and add insulation if necessary Contact the installer The pre heater overheating protection has tripped Find out the cause for the failure and reset the protection against overheating R but...

Страница 23: ...ts contact service External emergency shutdown Ventilation stopped with the emergency shutdown button If the building has an external shutdown switch check if it has been pressed Contact service Find...

Страница 24: ...24...

Страница 25: ...ant definitions and classification in annex VIII table 1 0 65 Declared maximum internal and external leakage rates for bidirec tional ventilation units 4 0 8 Position and description of visual filter...

Страница 26: ...26 2016 1254 2014 A B C D E F G A A B C D E F G ENERGIA ENERGIJA ENERGY ENERGIE ENERGI SVEA A 48 dB 619 m3 h...

Страница 27: ......

Страница 28: ...r Oy Kipin tie 1 FIN 06150 Porvoo Finland Tel 358 207 528 800 enervent enervent com www enervent com Exvent AS Ringeriksvei 195 N 1339 V yenenga Norge Tlf 67 10 55 00 exvent exvent no www exvent no ve...

Отзывы: