Operating and maintenance instructions for the ventilation unit

Some control panel functions are meant only 

for installation or maintenance use. Because  

these functions are not usually needed, they are 

password-protected.

FOR INFORMATION

What is the ventilation unit used for?

The unit is meant to improve the indoor air quality, mainly 
by ventilating.

The unit also recovers heat from the extract air. Some 
models can be used for cooling supply air during summer.  
The indoor humidity and carbon dioxide levels can be 
controlled with the unit.

How does the ventilation unit work?

Functioning ventilation is the basis for living comfortably. 
In mechanical ventilation, fresh air is blown into the 
house, and used air is blown out. The purpose of 
ventilation is to bring in clean, filtered air for people and 
pets to breathe, and to extract impurities from indoor air.

A rotating heat exchanger recovers heat energy from 
the extract air. The heat in the extract air warms up the 
aluminium vanes in the heat exchanger, which in turn 
releases the heat energy into the supply air when rotating, 
with an efficiency of over 80%.

How is the ventilation unit used?

When ventilation is carefully designed and installed, you 
do not have to do anything. Sit comfortably and enjoy the 
fresh air.

How do I begin to use the unit?

The ventilation system should be installed and ready for 
use.

Tap the control pane screen. Its keylock might be on. 
Open the lock by pressing the lock button for a few 
seconds. 

The main page of the control panel should open:

The main page of the control panel

The circle around the operating mode button changes 
its color depending on what the ventilation unit is doing. 
The circle is green, when heat recovery is active. The circle 
is orange and red when heating is active, and blue when 
cooling is active.

If the text 

Select language

 displays on the screen instead, 

the system has not been installed yet. In this case do 
not continue using the panel. Contact the installing 
technician instead.

If nothing happens when 
you tap the screen, the 
control panel battery may 
have run out, or the 
ventilation unit is 
switched off. Switch on 
the ventilation unit, or 
charge the battery by 
putting the panel in the 
wall mount, or connect 
a mobile charger (µUSB 
connector).

Содержание Svea eAir

Страница 1: ...Operating and maintenance instructions for the ventilation unit Svea eAir...

Страница 2: ...t Zehnder Oy 2019 Luvaton kopiointi ja levitys on kielletty Otill ten kopiering och distribution r f rbjuden Uautorisert kopiering og distribuering er forbudt Unauthorised copying and distribution is...

Страница 3: ...e ventilation to follow my schedule automatically 10 How can I save money and energy and advance the healthiness of my living environment 10 What other properties does the ventilation unit have 11 Wha...

Страница 4: ...used by persons including children with reduced physical sensory or mental capacity or without sufficient experience or knowledge unless a person responsible for their safety is supervising and advis...

Страница 5: ...the reason for the malfunction before restarting the unit When you have switched off the power to the unit wait for two 2 minutes before starting the maintenance work Even though the power is switched...

Страница 6: ...leaning the heat exchanger can be found in the Maintenance section If you encounter issues with using the ventilation unit check for answers in the Troubleshooting table at the end of this manual Alwa...

Страница 7: ...eases the heat energy into the supply air when rotating with an efficiency of over 80 How is the ventilation unit used When ventilation is carefully designed and installed you do not have to do anythi...

Страница 8: ...ntrol panel main page has the status At home If it is not so change it by doing the following 1 Tap the green circle in the middle of the main page of the control panel Choose operating mode window op...

Страница 9: ...or putting the children to bed you can switch on the Silent mode You must activate the Silent mode before it can be used for the first time Activating Silent mode 1 Tap the upward arrow on the main pa...

Страница 10: ...ogrammable functions 5 Tap the function you want The function setting window opens 6 Set the start and end times for the function 7 Tap the OK button A window listing the time programs displays and th...

Страница 11: ...emely cold conditions and when indoor air is very humid e g after using the shower and when drying laundry If you are suspecting that the ventilation system settings need to be updated contact the sys...

Страница 12: ...ther values are not editable Menu Description of change Usage mode settings Setting the boost time in the Manual boost settings Setting the overpressure time in the Manual overpressure settings Activa...

Страница 13: ...warm If the air flowing from the ventilation is too warm 1 Tap the minus symbol on the main page of the control panel The temperature reading on the panel changes and the ventilation system begins to...

Страница 14: ...ot working If controlling the ventilation unit with the control panel is not working check that the control panel battery is not run out If the battery is empty recharge it by placing the control pane...

Страница 15: ...m of the screen and then tap the Alarms icon 2 Alarms menu opens and the new alarm is shown first in the list At first glance you can see which alarm was sent when the alarm was sent If you need more...

Страница 16: ...intenance Sufficient maintenance usually covers the following tasks changing filters cleaning the heat exchanger when sweeping the ventilation ductwork cleaning the fans when sweeping the ventilation...

Страница 17: ...17 Operating and maintenance instructions for the ventilation unit Changing filters 2 3 4 1 ISO ePM1 F7 ISO ePM10 M5...

Страница 18: ...e unit after cleaning Heat exchanger Inspecting Before opening the service hatch always make sure that the unit s supply voltage is switched off DANGER 1 Check the condition of the heat exchanger visu...

Страница 19: ...rew the six screws on the heat exchanger maintenance hatch lid at the front side of the heat exchanger 6 Inspect the belt wheel to make sure it is undamaged in its place and rotating properly 7 Clean...

Страница 20: ...e that the belt is in its place and everything looks fine 16 Vacuum clean the heat exchanger casing Rotate the heat exchanger when you are vacuuming to be sure to clean everywhere 17 Close the mainten...

Страница 21: ...s located in the electric box of the unit Contact service HRW pulley has separated from the shaft Check from the HRW round opening if the shaft is rotating empty and the pulley is in its place Contact...

Страница 22: ...air ducts and add insulation if necessary Contact the installer The pre heater overheating protection has tripped Find out the cause for the failure and reset the protection against overheating R but...

Страница 23: ...ts contact service External emergency shutdown Ventilation stopped with the emergency shutdown button If the building has an external shutdown switch check if it has been pressed Contact service Find...

Страница 24: ...24...

Страница 25: ...ant definitions and classification in annex VIII table 1 0 65 Declared maximum internal and external leakage rates for bidirec tional ventilation units 4 0 8 Position and description of visual filter...

Страница 26: ...26 2016 1254 2014 A B C D E F G A A B C D E F G ENERGIA ENERGIJA ENERGY ENERGIE ENERGI SVEA A 48 dB 619 m3 h...

Страница 27: ......

Страница 28: ...r Oy Kipin tie 1 FIN 06150 Porvoo Finland Tel 358 207 528 800 enervent enervent com www enervent com Exvent AS Ringeriksvei 195 N 1339 V yenenga Norge Tlf 67 10 55 00 exvent exvent no www exvent no ve...

Отзывы: