I want the ventilation to follow 

my schedule automatically

If your life has a regular rhythm, you can make things 
easier by configuring some of the ventilation functions 
to activate automatically at certain times. The following 
functions can be timed:

Function

Description

Away

Ventilation unit can be configured to operate 

in 

Away

 mode by using a time program, for 

example during working days when nobody 

is at home.

Heating 

prevented

Heating is prevented at certain time. This 

mode is practical in the summer, for example, 

when sudden changes in temperature 

can activate heating even though it is not 

needed.

Cooling 

prevented

Cooling is prevented at certain time. This 

function is useful in the spring, for example, 

when sudden changes in temperature can 

trigger cooling even though is not needed. 

Temperature 

drop

Ventilation is functioning at a normal level, 

but allows the indoor temperature to drop.

Time relay

Sets time relay (DO7) to activate at a certain 

time. The function can only be used if 

the installer has made the neccessary 

connections for the desired function.

Boost

The ventilation unit will boost ventilation 

during the time defined in the time program.

To schedule functions:

1.  Tap the upward arrow on the main page of the 

control panel. 

Main menu

 window opens.

2.  Tap the 

Time programs

 icon. You can choose from 

weekly and annually run programs.

3.  Tap 

New weekly program

 or 

New annual program

.

4.  Tap 

Not selected

 to display a list of programmable 

functions.

5.  Tap the function you want. 

The function setting window opens.

6.  Set the start and end times for the function.
7.  Tap the 

OK

 button. 

A window listing the time programs displays, and the 
time program you created is shown on the screen.

How can I save money and 

energy, and advance the 

healthiness of my living 

environment?

Correctly designed and used ventilation saves money 
and energy. Additionally, it promotes healthy living 
environments and healthy inhabitants.

• 

Use the ventilation system according to the designed 
plan throughout the year.

• 

Clean or change the filters at set intervals and vacuum 
the inside of the unit regularly. Dust and other air 
impurities can contaminate the unit. Dirt blocks the 
filters and adheres to the heat exchanger, which 
in turn weakens the efficiency of ventilation. The 
ventilation unit service door needs to be opened 
regularly - once a month, for example - and the 
condition of the unit must be checked.

• 

Use special modes like 

Silent

 and 

Overpressure

 only 

when they are really needed. Unnecessary use of 
special modes will show in your electric bill.

• 

Besides controlling the ventilation system, you 
can add to your comfort by traditional means. For 
example, closing curtains and windows on a hot 
day, or dressing warm on cold days can save a lot of 
energy.

• 

Use only Enervent-approved spare parts.

The ventilation system Eco mode saves energy and 
money without compromising air quality.

The control panel main screen displays a time program reminder two hours before the program starts. When the 

ventilation unit is operating under a time program, the panel main screen displays a clock symbol.

FOR INFORMATION

Содержание Svea eAir

Страница 1: ...Operating and maintenance instructions for the ventilation unit Svea eAir...

Страница 2: ...t Zehnder Oy 2019 Luvaton kopiointi ja levitys on kielletty Otill ten kopiering och distribution r f rbjuden Uautorisert kopiering og distribuering er forbudt Unauthorised copying and distribution is...

Страница 3: ...e ventilation to follow my schedule automatically 10 How can I save money and energy and advance the healthiness of my living environment 10 What other properties does the ventilation unit have 11 Wha...

Страница 4: ...used by persons including children with reduced physical sensory or mental capacity or without sufficient experience or knowledge unless a person responsible for their safety is supervising and advis...

Страница 5: ...the reason for the malfunction before restarting the unit When you have switched off the power to the unit wait for two 2 minutes before starting the maintenance work Even though the power is switched...

Страница 6: ...leaning the heat exchanger can be found in the Maintenance section If you encounter issues with using the ventilation unit check for answers in the Troubleshooting table at the end of this manual Alwa...

Страница 7: ...eases the heat energy into the supply air when rotating with an efficiency of over 80 How is the ventilation unit used When ventilation is carefully designed and installed you do not have to do anythi...

Страница 8: ...ntrol panel main page has the status At home If it is not so change it by doing the following 1 Tap the green circle in the middle of the main page of the control panel Choose operating mode window op...

Страница 9: ...or putting the children to bed you can switch on the Silent mode You must activate the Silent mode before it can be used for the first time Activating Silent mode 1 Tap the upward arrow on the main pa...

Страница 10: ...ogrammable functions 5 Tap the function you want The function setting window opens 6 Set the start and end times for the function 7 Tap the OK button A window listing the time programs displays and th...

Страница 11: ...emely cold conditions and when indoor air is very humid e g after using the shower and when drying laundry If you are suspecting that the ventilation system settings need to be updated contact the sys...

Страница 12: ...ther values are not editable Menu Description of change Usage mode settings Setting the boost time in the Manual boost settings Setting the overpressure time in the Manual overpressure settings Activa...

Страница 13: ...warm If the air flowing from the ventilation is too warm 1 Tap the minus symbol on the main page of the control panel The temperature reading on the panel changes and the ventilation system begins to...

Страница 14: ...ot working If controlling the ventilation unit with the control panel is not working check that the control panel battery is not run out If the battery is empty recharge it by placing the control pane...

Страница 15: ...m of the screen and then tap the Alarms icon 2 Alarms menu opens and the new alarm is shown first in the list At first glance you can see which alarm was sent when the alarm was sent If you need more...

Страница 16: ...intenance Sufficient maintenance usually covers the following tasks changing filters cleaning the heat exchanger when sweeping the ventilation ductwork cleaning the fans when sweeping the ventilation...

Страница 17: ...17 Operating and maintenance instructions for the ventilation unit Changing filters 2 3 4 1 ISO ePM1 F7 ISO ePM10 M5...

Страница 18: ...e unit after cleaning Heat exchanger Inspecting Before opening the service hatch always make sure that the unit s supply voltage is switched off DANGER 1 Check the condition of the heat exchanger visu...

Страница 19: ...rew the six screws on the heat exchanger maintenance hatch lid at the front side of the heat exchanger 6 Inspect the belt wheel to make sure it is undamaged in its place and rotating properly 7 Clean...

Страница 20: ...e that the belt is in its place and everything looks fine 16 Vacuum clean the heat exchanger casing Rotate the heat exchanger when you are vacuuming to be sure to clean everywhere 17 Close the mainten...

Страница 21: ...s located in the electric box of the unit Contact service HRW pulley has separated from the shaft Check from the HRW round opening if the shaft is rotating empty and the pulley is in its place Contact...

Страница 22: ...air ducts and add insulation if necessary Contact the installer The pre heater overheating protection has tripped Find out the cause for the failure and reset the protection against overheating R but...

Страница 23: ...ts contact service External emergency shutdown Ventilation stopped with the emergency shutdown button If the building has an external shutdown switch check if it has been pressed Contact service Find...

Страница 24: ...24...

Страница 25: ...ant definitions and classification in annex VIII table 1 0 65 Declared maximum internal and external leakage rates for bidirec tional ventilation units 4 0 8 Position and description of visual filter...

Страница 26: ...26 2016 1254 2014 A B C D E F G A A B C D E F G ENERGIA ENERGIJA ENERGY ENERGIE ENERGI SVEA A 48 dB 619 m3 h...

Страница 27: ......

Страница 28: ...r Oy Kipin tie 1 FIN 06150 Porvoo Finland Tel 358 207 528 800 enervent enervent com www enervent com Exvent AS Ringeriksvei 195 N 1339 V yenenga Norge Tlf 67 10 55 00 exvent exvent no www exvent no ve...

Отзывы: