4  Certification and warranty

Warranty conditions

The unit is covered by a manufacturer’s warranty for 
a period of 24 months after fitting up to a maximum 
of 30 months after the date of manufacture. Warranty 
claims may only be submitted for material faults 
and/ or construction faults arising during the 
warranty period. In the case of a warranty claim, 
the unit must not be dismantled without written 
permission from the manufacturer. Spare parts are 
only covered by the warranty if they were supplied 
by the manufacturer and have been installed by an 
approved installer.

The warranty becomes invalid if:

  The guarantee period has elapsed;

  The unit is used without filters;

  Parts are used that have not been supplied by the 

manufacturer;

  Non-authorised changes or modifications have 

been made to the unit;

  Installation has not been carried out according to 

the applicable regulations;

  The defects are due to incorrect connection, 

inexpert use, or contamination of the system.

On-site (dis)assembly costs are not covered by the 
terms of the warranty. This also applies to normal 
wear and tear. Zehnder retains the right to change 
the construction and/or configuration of its products 
at any time without being obliged to alter previously 
delivered products.

Liability

The unit has been designed and manufactured for 
use in balanced ventilation systems incorporating 
Zehnder heat recovery systems. Any other 
application is seen as inappropriate use and can 
result in damage to the unit or personal injury, for 
which the manufacturer cannot be held liable. The 
manufacturer is not liable for any damage originating 
from: 

  Non-compliance with the safety, operating and 

maintenance instructions in this document;

  The use of components not supplied or 

recommended by the manufacturer.

 

Responsibility for the use of such components lies 
entirely with the installer;

  Normal wear and tear.

Disposal

 Dispose of the unit in an 

environmentally friendly manner. 
Do not dispose of the unit with your 
domestic waste.

1.  Contact the supplier about the possibilities to 

return the unit.

2. If the unit cannot be returned, check the local 

regulations for the options on recycling the 
components.

3. Do not dispose of the batteries from the wireless 

(RF) operating devices as normal waste. They 
must be discarded at designated disposal 
locations.

CE certification

Zehnder Group Nederland B.V.
Lingenstraat 2 • 8 028 PM Zwolle-NL
T +31 (0)38 4296911 • F + 31 (0)38 4225694
Company register Zwolle 05022293

 

EEC declaration of conformity

Machine description

  

Heat recovery units: 

ComfoAir Q series

Complies with the following directives 

 

Machinery Directive  

(2006/42/EEC)

 

Low Voltage Directive  

(2006/95/EEC)

 

EMC Directive  

 

(2004/108/EEC)

Zwolle, 04-04-2016
Zehnder Group Nederland B.V.

A.C. Veldhuijzen,
Head of R&D
Competence Center ComfoSystems

Содержание ComfoAir Q

Страница 1: ...Cooling Fresh Air Clean Air Heating Ventilation system Zehnder ComfoAir Q Manual for the user ComfoAir Q TR ComfoAir Q ST...

Страница 2: ...age of this document Use of the unit The unit may only be used when it is properly installed according to the instructions and guidelines in the installer manual of the unit The unit can be used by ch...

Страница 3: ...tting the comfort options 15 3 5 1 Temperature profile 15 3 5 2 Scheduler 16 3 5 3 Bypass heat recovery for a specific duration 18 3 5 4 Stop ComfoCool Q for a specific duration 18 3 6 Checking the st...

Страница 4: ...g the internal filters 28 5 5 1 View filter status 28 5 5 2 Postponing filter warning 28 5 5 3 Replacement instruction 29 6 Malfunctions 30 6 1 Airflow is not as expected 31 6 2 Condensation on the ou...

Страница 5: ...to the unit can occur Do not open the casing The installer makes sure that all parts that can cause personal injury are behind the casing The installation commissioning and maintenance must be carried...

Страница 6: ...receiver Zehnder ComfoSwitch C 55 For basic remote manual and automatic control of the unit The automatic control is based on the unit settings This is a wired control Zehnder ComfoSwitch C 67 For ba...

Страница 7: ...KNX connectivity options Zehnder ComfoConnect LAN C Provides LAN connectivity options for remote control with the ComfoControl app Zehnder ComfoCool Q600 Decreases the temperature and pre conditions...

Страница 8: ...light On The unit is operating correctly Off The unit has no power or the display is in use Slowly flashing every second Warning Change filters or SERVICE MODE active Rapidly flashing four times a se...

Страница 9: ...d control G Current ventilation mode AUTO the airflow is set by the scheduler MANUAL the airflow is set by the user H Temporary override of the SCHEDULER VENTILATION I Current fan mode no icon both fa...

Страница 10: ...FROST PREHEATER3 SEASON DETECTION2 BYPASS RF SETTINGS2 8 COMFOCOOL3 ANALOG INPUT3 SUBSOIL HEAT EXCH 3 COMFOCOOL3 SEASON DETECTION FANS ENERGY INSTALLER DEFAULT2 TASK MENU 1 This menu is only visible...

Страница 11: ...Access the unit display To save energy the unit display screen will be off most of the time The display will automatically turn off after 15 minutes of no activity The following actions will make the...

Страница 12: ...hapter How to navigate through the unit menu 2 Navigate to AUTO MANUAL 3 Navigate to MANUAL 4 Select the desired airflow with the up and down button A away if the house will be empty 1 low if you want...

Страница 13: ...the chapter How to navigate through the unit menu 2 Navigate to VENTILATION 3 Navigate to SUPPLY ONLY if you would like to stop extracting air EXTRACT ONLY if you would like to stop supplying air if a...

Страница 14: ...you will come home to a comfortable and fresh house e g after a long holiday 1 Navigate to TASK MENU as instructed in the chapter How to navigate through the unit menu 2 Navigate to AWAY 3 Navigate t...

Страница 15: ...unit are set to provide a comfort level desired by the average person 3 5 1 Temperature profile The amount of heat recovery is controlled automatically based on the set temperature profile The effect...

Страница 16: ...ram is the leading program and overrules any longer program If both overlapping programs have an equally long period the program with the highest airflow PRESET will be the leading program When no sch...

Страница 17: ...program will end the next day 10 Select CONFIRM after each number 11 Navigate to your desired preset for the defined timeslot AWAY airflow if the house will be empty 1 airflow if you want low ventilat...

Страница 18: ...IVATED if you would like to maximise the heat recovery as much of the heat from the extracted air will be transferred back to the supply air as possible 4 Select the desired duration with the up and d...

Страница 19: ...BYPASS The unit is running at a lower airflow rate than normal due to a request from the bypass See chapter Heat recovery control bypass for a specific duration for more information about the bypass c...

Страница 20: ...fans PREHEATER view the current electrical consumption of the preheater YEAR TO DATE view the energy consumption of the fans since the beginning of the year TOTAL view the total energy consumption of...

Страница 21: ...Navigate to the desired language 3 9 Setting the unit display brightness 1 Navigate to BASIC OPTIONS as instructed in the chapter How to navigate through the unit menu 2 Navigate to BRIGHTNESS 3 Navi...

Страница 22: ...all settings in the TASK MENU excluding the set scheduler s will be returned to the default factory settings RESET INCL SCHEDULE You can find this menu under RESET ALL TASKS When this menu is activat...

Страница 23: ...etting ON For AUTO mode setting AUTO ONLY or ON It is cooling season The indoor temperature is significantly higher than the temperature outside The bypass control is in AUTO mode The ComfoCool is tur...

Страница 24: ...it is equipped with a function to detect the current season The detection is based on the RMOT5 In the menu SEASON DETECTION2 you can set the RMOT5 temperature on which the HEATING SEASON2 and COOLING...

Страница 25: ...d manufactured for use in balanced ventilation systems incorporating Zehnder heat recovery systems Any other application is seen as inappropriate use and can result in damage to the unit or personal i...

Страница 26: ...to be compromised Keep a clearance in front of the unit of at least 1m This room is needed to carry out the maintenance activities 1m 5 1 Fill the condensation drain The condensation drain is connecte...

Страница 27: ...ce 3 Remove the filter behind the valve if present 4 Clean the valve with a soft brush vacuum cleaner or soapy water 5 Rinse the valve and then dry 6 Replace the filter behind the valve if present 7 P...

Страница 28: ...Navigate to FILTERS as instructed in the chapter How to navigate through the unit menu 2 Navigate to FILTER STATUS 5 5 2 Postponing filter warning When the unit is displaying the message EXPECT FILTER...

Страница 29: ...new supply filter with the arrow pointing up into the unit Insert new extract filter with the arrow pointing up into the unit Insert filter caps Place the click connection of the filter caps on top of...

Страница 30: ...ow to navigate through the unit menu 2 Wait for 2 minutes If the error reoccurs 3 Navigate to STATUS 4 Navigate to ERRORS 5 Write down all the malfunction code s Select NEXT to view more errors 6 Sele...

Страница 31: ...unit 6 2 Condensation on the outside of the unit and or air ducts When the unit is installed in an area with a higher average humidity such as bathroom or wc the probability of condensation on the out...

Страница 32: ...type Measured by Unit type Return Room Position Required m3 h Tested m3 h Type valve Settings valve Kitchen Bathroom Toilet Total Supply Room Position Required m3 h Tested m3 h Type valve Settings va...

Страница 33: ...tivity Y1 Y2 Y3 Y4 Y5 Y6 Y7 Replace the filters Clean the valves Clean the grilles Clean the valves and grilles Clean the operating device Fill the condensation drain of the domestic waste water syste...

Страница 34: ...Y9 Y10 Y11 Y12 Y13 Y14 Replace the filters Clean the valves Clean the grilles Clean the valves and grilles Clean the operating device Fill the condensation drain of the domestic waste water system Ins...

Страница 35: ...EN 35 Data Activity Initials...

Страница 36: ...hland GmbH Sales International Almweg 34 77933 Lahr Germany T 49 78 21 586 392 F 49 78 21 586 406 sales international zehndergroup com www international zehnder systems com ZGNL_Manual_40015974 V0118...

Отзывы: