24 - EN
3.11.3 TEMPERATURE PROFILE2
In the advanced TEMPERATURE PROFILE2
menu you can influence the temperature of
the different temperature profiles (WARM,
NORMAL and COOL) which you can set in
the TASK MENU.
First choose which temperature profile mode you
would like to use in the menu SET MODE2:
■
ADAPTIVE = The desired indoor temperature
varies with the outdoor climate (adaptive comfort
technology);
■
FIXED = The desired indoor temperature is fixed
and does not depend on the outdoor climate.
In the ADAPTIVE mode the unit uses the RMOT5 for
determining the desired indoor temperature. You
can only influence this desired indoor temperature
by 1.5°C from the NORMAL setting by activating the
temperature profile COOL or WARM. The NORMAL
setting is 21.5°C @ 0°C RMOT5. For every °C
increase in RMOT5 the temperature is adjusted by
+0.11°C.
If you choose the FIXED mode you can set the
temperature for each temperature profile in the
FIXED PRESETS2 menu.
Temperature
profiles
Default value
FIXED
Value ADAPTIVE
WARM
24°C / 76°F
1.5°C
NORMAL
20°C / 68°F
-
COOL
18°C / 64°F
NORMAL -1.5°C
3.11.4 UNITS2
In the menu UNITS2 you can change the displayed
units of the temperature and airflow rate.
Menu item
Default value
TEMPERATURE2
CELSIUS
FLOW2
l/s
3.11.5 SEASON DETECTION2
To prevent the unit from counteracting with
external heating (e.g. central heating) and
cooling (e.g. air conditioner) units in the
dwelling, the unit is equipped with a function to
detect the current season. The detection is based on
the RMOT5. In the menu SEASON DETECTION2 you
can set the RMOT5 temperature on which the
HEATING SEASON2 and COOLING SEASON2 will
start.
By selecting the option STARTS NOW you can start
the season mode right away which will save the
current RMOT5 as the desired new season limit.
Menu item
Default value
HEATING LIMIT RMOT5
11°C / 51°F
COOLING LIMIT RMOT5
20°C / 68°F
3.11.6 RF SETTINGS2,8
In the RF SETTINGS2,8 menu you can set
the control options of the RF-signals. The
set control option is the same for all
connected RF ancillaries.
In the menu RF SENSOR PRIORITY2,8 you can set
when the unit will respond to a RF-signal:
Menu item
Function
ON
The unit will respond to
the RF-signal in AUTO and
MANUAL mode.
AUTO ONLY
The unit will only respond to
the RF-signal in AUTO mode.
When the unit is switched
to manual mode the unit will
ignore the RF-signal.
OFF
The unit will ignore the RF-
signal.
In the menu RF SENSOR FUNCTION2,8 you can set
how the unit will respond to a RF-signal:
Menu item
Function
FLOW PROPORTIONAL
The unit will translate the
signal from a RF sensor to a
corresponding airflow between
the starting and maximal set
airflow.
FLOW PRESET
The unit will translate the
signal from a RF sensor to one
of the preset airflows8.
2 This menu is only visible when the advanced mode is active.
3 This menu is only visible when the ancillary is connected to the unit.
5 RMOT = running mean outdoor temperature (average temperature over
past five days).
8 This menu is only visible when the unit has RF functionality.