WARNING

 

Risk of injury from touching the fan during operation 

Without an exterior wall panel, the fan is freely accessible and there is a risk of contact. 
Make sure that the ventilation unit is disconnected from the power supply.

 

 

Notes on operation of the ventilation unit 

  Standard operation of the unit 

This unit can be used by children aged 8 and over and also persons with reduced physical, sensory or mental abilities, or 
a lack of experience and knowledge provided that they are under supervision or have been instructed on the safe use of 
the unit and understand the risks that result from it. Children must not play with the unit. Children must not carry out cleaning 
and user maintenance without supervision. 

 Operating 

variants 

The ComfoAir 70 offers the following variants that can be combined for convenient operation: 

 

Operation on the unit – standard version with internal control panel. 

 

Operation with ComfoLED – optional: External, wired control panel (max. cable length 25 m). 

 

Radio-based operation – optional: Radio networking via RF module, connection hub and Zehnder Connect app. 

NOTE

 

The external control panel and the connection hub are only suitable for use in indoor areas.

 

 Proper 

use 

 

The ComfoAir 70 is intended for the ventilation of living rooms and spaces with a similar use. Any other use or any 
use beyond this is considered improper use. 

 

The ventilation unit is intended for use in rooms with a humidity level of approx. 40% to approx. 70% RH. It must not 
be installed in rooms where the relative air humidity is permanently above 80% during operation. 

 

The ventilation unit is not suitable for smoke extraction or drying buildings, for rooms with aggressive and corrosive 
gases or for rooms with extreme dust levels. 

 

The ventilation unit may only be operated when fully assembled with all the components (including facade finish). 

 

Intended use also includes observing all instructions in the user manual. 

In the event of improper use, the Zehnder Group accepts no liability for any damage that may occur and no warranty for 
the proper and functional operation of the ventilation unit. 

 

Guarantee conditions, warranty and liability 

 Guarantee 

conditions 

The manufacturer grants a guarantee of 24 months from installation or a maximum of 30 months from the date of 
manufacture on the device. Warranty claims may only be asserted for material defects and/or design faults that have 
occurred during the warranty period. 
The costs of removal and installation on site are not covered by the warranty. The same applies to natural wear and tear. 
Zehnder reserves the right to change the design and/or configuration of its products at any time with no obligation to adjust 
products already supplied accordingly. 

 Warranty 

In the event of a warranty claim, the unit must not be disassembled without the written consent of the manufacturer. Spare 
parts are only covered by the warranty if they have been supplied by the manufacturer and fitted by an approved technician. 

The warranty shall be null and void if: 

 

The warranty period has elapsed. 

 

The installation has not been carried out in accordance with the applicable regulations.  

 

The unit is operated without a filter and without a facade finish. 

 

Original parts have been replaced by non-original parts. 

 

Unauthorised changes or modifications to the unit have been made. 

 

The defects are due to improper installation, improper use or neglected maintenance of the system. 

 Liability 

The ComfoAir 70 is intended for the ventilation of apartments, offices and similar rooms. Every other use is deemed as 
"improper use", and can lead to damaging the ComfoAir 70, or to personal injury, for which the manufacturer cannot be 
held liable. 

The liability of the manufacturer becomes null and void in the following cases: 

 

Failure to observe the instructions specified in this manual pertaining to safety, operation and maintenance. 

Содержание ComfoAir 70

Страница 1: ...Decorative Radiators Comfortable indoor ventilation Heating and cooling ceiling systems Clean air solutions User manual on operation and installation for operators and installers Zehnder ComfoAir 70...

Страница 2: ...the property of Zehnder Group Publication as a whole or in parts requires the written approval of Zehnder Group In house duplication designated for the evaluation of the product or for proper use is p...

Страница 3: ...ng functions and signals 7 Options for ventilation operation 10 External control panel 10 Operation via networking 10 Automatic operation via sensor module 10 Maintenance by the user 11 Filter mainten...

Страница 4: ...ciently qualified for the respective work involved Qualification of target group 1 3 1 1 Users Users must be instructed by qualified personnel as follows Instruction in hazards when handling electrica...

Страница 5: ...supply unless instructions to the contrary are listed in the manual Following installation all parts that could lead to personal injury are protected by the housing The unit cannot be opened without...

Страница 6: ...acade finish Intended use also includes observing all instructions in the user manual In the event of improper use the Zehnder Group accepts no liability for any damage that may occur and no warranty...

Страница 7: ...esigned for permanent operation and is only to be taken out of operation for maintenance and repair work With the appropriate optional sensor technology in the unit fully automatic demand controlled v...

Страница 8: ...e Operating and display elements of the control panel The control panel has touch sensitive buttons and LED status indicators NOTE The ventilation unit can be operated at the same time with the intern...

Страница 9: ...unit runs at the lowest ventilation level 15 m h This fan speed can be selected when away and for the purpose of moisture protection NOTE A cyclically limited reduced ventilation can be set with the A...

Страница 10: ...rarily activated fan speed 4 can only be activated with a configured DIP switch setting After the boost ventilation time has elapsed the unit will be transferred to the most recently selected fan spee...

Страница 11: ...ing of most recently active fan speed when supply air fan is switched off Display of LED1 3 as example Frost protection mode From an outside air temperature of 4 C the frost protection function is aut...

Страница 12: ...l unit are possible Automatic operation via sensor module The application of the Automatic function follows the logic of a demand controlled system for optimizing the indoor air quality Consequently a...

Страница 13: ...separately if needed in accordance with the humidity or air quality control The HUMIDITY sensor technology is primarily supposed to be installed in units for the ventilation of rooms with an increase...

Страница 14: ...with the relevant filter maintenance LED signal 1 Put the unit into the Standby operating mode 2 Remove the upper design cover by pulling it out of the guides in an upwards direction 3 Use your finge...

Страница 15: ...of the ventilation unit and the operating surface of the control panel which should be wiped down from time to time using a soft damp cloth never just wipe dry WARNING Risk due to electric shock Disco...

Страница 16: ...mediately Included in the scope of delivery are ComfoAir 70 including installation kit Facade finish including installation set Mounting template as imprint on the inside of the lid of the box User ma...

Страница 17: ...r supply a mains cable recommended type NYM J 3x1 5 for stationary units with disconnection with a contact opening width corresponding to the conditions of overvoltage category III for full disconnect...

Страница 18: ...g piece must protrude so far out of the wall so that the connector with the attached sealing tape is inserted in the EPP housing section 4 2 3 2 Side connection of the ventilation tube If the ventilat...

Страница 19: ...wer supply before carrying out installation and maintenance work Proceed as follows for the installation of the unit NOTE Remove the transport lock attached to protect the lid mechanism Follow the ins...

Страница 20: ...the wall bracket 6 Screw the wall bracket to the inner wall and take care to ensure that the mains supply line and if present the cable for the external control panel are located in the area of the ca...

Страница 21: ...sertion of the ventilation unit it is recommended to wet the wall mounting pipe using silicone spray 10 Pivot the lower design cover against the EPP housing In the process press the lower design cover...

Страница 22: ...the mains supply line and the power supply unit s primary side power cable into the connection socket DANGER Danger due to electric shock The wires for the mains supply line and the wires for the prim...

Страница 23: ...the complete EPP housing of the ventilation unit into the wall mounting tube up to a distance of approx 15 cm from the wall bracket so that the control board is still freely accessible 6 Connect the...

Страница 24: ...the exterior wall panel as a facade finish WARNING Danger due to falling exterior wall panel The exterior wall panel is to be fixed using the supplied mounting accessories or with mounting material s...

Страница 25: ...ar contour of the airflow openings on the bottom cover NOTE To protect against water ingress apply a thick bead of suitable sealant e g weather resistant acrylic to the bottom cover depending on the s...

Страница 26: ...d out at two yearly maintenance intervals NOTE Instructions for proper disinfection can be found at www core life In doing so proceed as follows 1 Disconnect the ComfoAir 70 from the supply voltage 2...

Страница 27: ...esidual water can drain out of the openings 7 Following the inspection install all parts in the reverse order NOTE If necessary dismantled ventilation tubes must be reconnected in an air tight manner...

Страница 28: ...ess min 275 mm to max 600 mm to 900 mm with extension set Mounting position In wall casing with supply and exhaust air openings at the top Operation data Fan speed Volume flow m h Thermal efficiency H...

Страница 29: ...27 Dimensions with optional radio module 440 442 145 795 50 SUPPLY AIR EXTRACT AIR OUTDOOR AIR EXHAUST AIR 380 660 EXTRACT AIR SUPPLY AIR 376 Optional air tube connections on the back...

Страница 30: ...28 Terminal scheme...

Страница 31: ...ehnder Group Deutschland GmbH Almweg 34 77933 Lahr Deutschland T 49 7821 586 392 F 49 7821 586 406 sales international zehndergroup com www international zehnder systems com PDE Manual_CA70_V1 9_V0621...

Отзывы: