8
Icon
Description
Explanation
LED1-4 light up
Fan speed 4 (FS4) Intensive ventilation
The ventilation unit runs at maximum ventilation level (60 m³/h). This fan
speed is used for a fast air exchange.
NOTE
Intensive ventilation for a limited period of time can be set with the
boost ventilation operating mode.
AUTO LED lights up
Automatic
operating mode
(AUTO)
NOTE
The Automatic function can only be activated with a sensor module.
Touching the (+) key from the currently active FS4 transfers the unit to
AUTO fan speed. AUTO fan speed is excited by touching the (-) button,
and the unit is transferred back to FS4. The Automatic function is
visualized by the Automatic LED.
AUTO LED lights up
Bathroom function
operating mode
NOTE
The Bathroom function can only be activated with a sensor module
and configured DIP switch setting.
The fans are operated at maximum speed starting from a relative room
air humidity of 80%. If this limit is not reached, the previously active
operating mode is applied again.
LED1-4 light up
Boost ventilation
mode
NOTE
The boost ventilation function as temporarily activated fan speed 4 can
only be activated with a configured DIP switch setting.
After the boost ventilation time has elapsed, the unit will be transferred
to the most recently selected fan speed. The fan speed that was active
for longer than 10 s is deemed as the last fan speed. When boost
ventilation is active, the operating modes "Extract air mode" or "Supply
air mode", that may be activated, are retained.
The duration of the boost ventilation function can be set between 5 and
120 minutes by the customer service team using the programming
module.
(Factory setting: 15 minutes)
LED1 lights up
during the active
time phase
Away mode
NOTE
The Away function as temporarily activated fan speed 1 can only be
activated with a configured fan speed 1.
The active operating time of the FS1 can be set between 15 and 59 min/h
by the customer service team using the programming module.
(Factory setting: 60 min/h
≙
FS1 permanent operation).
LED display for
energy-saving
mode
The LED display on the control panel changes after 10 seconds into
energy-saving mode without operator input (unit functions remain active;
the LED display is switched off). If any key is touched, the LED indicator
will be activated again. Touching the button brings about no change to
the operating mode, however.