16
3 Hints for qualified personnel
This section describes how to install and commission the ComfoAir 70, how to analyse errors and how to
carry out special maintenance work.
3.1 Installation requirements
For proper installation, the following requirements must be fulfilled:
•
Assembly in accordance with the general and on-site safety and installation instructions, amongst
others of the electric power station and water works as well as in accordance with the instructions
contained in this operating manual.
•
Frost-free room in the interior
•
Voltage supply 230 Vac, 50-60 Hz
•
Sufficient space for air duct connections and maintenance work
•
Possibility of an all phase cut must be assured
3.1.1 Transport and packing
Proceed with care when transporting and unpacking the ComfoAir 70. The wall installation tube includes the
package and can be installed in advance independent of the main device. The main device is packed in a foil
dust free. Do not damage the package before the installation of the main device.
The packaging of the device may only be removed immediately before assembly! Prior to and
during assembly interruptions, the open air duct connection stubs must be protected against
ingress of construction dust and moisture!
3.1.2 Checking the Scope of Delivery
If damages or incompleteness should be determined at the delivered product then contact the supplier
immediately.
The scope of delivery includes the following:
•
WRG ComfoAir 70 including fixing material
•
Power supply unit 230 VAC, 50-60 Hz 24 VDC on the device
•
Original operating manual
•
Combo- external wall grid including fixing material and assembly material
•
Plastic wall installation tube
•
Assembly template on the interior of the carton cover
During the installation of the air ducts, the accessory of Zehnder Product Program should be accessed for
devices with two-room connection.
3.2 Assembly
The wall-hanging assembly is permitted exclusively for ComfoAir 70. The device should thereby be also
appropriate in vertical position.
Use the assembly templates as an aid for drilling.
The device is delivered as pre-installed. Disassemble the upper and lower design-cover hoods before
installation the device.
3.2.1 Assembly Preparations
1.
Select a suitable assembly location (sufficient distance from the furniture and delimiting walls) on the
outside wall and bore a hole with a diameter of 280 mm for installing wall-installation tube (external
diameter 250 mm) in the outside wall.