2 - EN

Foreword

 Read this document carefully before use. 

This document provides all the information required 
for safe and optimal installation of the ComfoD 180 
and ComfoAir180. In this document they will be 
referred to as “the unit”. 
The unit is subject to continuous development and 
improvement. As a result, the unit may slightly differ 
from the descriptions.

The following pictograms are used in this 
document:

 Point of attention.

  Risk of:

 

- damage to the device;

 

-  performance of the device is compromised if 

instructions are not observed carefully.

 Risk of personal injury for the user.

 Maintenance

 Questions

Please contact the supplier if you have any questions 
or would like to order a new document or new filters. 
The contact details of the main supplier(s) can be 
found in the user manual.
The contact details of the manufacturer can be found 
in the back of this document.

The following information can be found in the 
user manual:

User Information

General information about the ventilation system.

Operating devices available for the unit.

Warranty and liability conditions.

EEC declaration of conformity.

How to maintain the filters of the unit.

How to maintain the valves of the ventilation system.

The following information can be found on the 
identification plate:

Meaning of the suffixes

ComfoAir

Product family name.

ComfoD

The unit has a display installed as default.

180

Product type name.
(Air volumes in m3/h)

Luxe

The unit has no display.

Enthalpie

The unit has an enthalpy exchanger installed 
as default.

ERV

The unit has an enthalpy exchanger installed 
as default.

PH

The unit has a pre heater installed as default.

V

The unit has a pre heater installed as default.

All rights reserved.

This documentation has been compiled with the utmost care. The publisher cannot be held liable for any damage 
caused as a result of missing or incorrect information in this document. In case of disputes the English version of 
these instructions will be binding.

Содержание ComfoAir 180

Страница 1: ...Cooling Fresh Air Clean Air Heating Ventilation system ComfoD 180 and ComfoAir 180 Manual for the commisioning and service engineer ComfoD Basic ComfoAir Luxe...

Страница 2: ...following information can be found in the user manual User Information General information about the ventilation system Operating devices available for the unit Warranty and liability conditions EEC d...

Страница 3: ...13 3 4 Fire place program P50 13 3 5 Enthalpy exchanger P59 13 4 Technical specifications 14 4 1 Service parts 15 4 2 Dimension sketch 16 4 3 Wiring diagram 18 5 Maintenance 4 3 Wiring diagram 20 5 1...

Страница 4: ...4 EN...

Страница 5: ...e The P menus can be accessed by the display read out software or ComfoSense P menus P1 P2 and P9 can be accessed by the user mainly to read statuses and set time delays The remaining P menus P3 to P8...

Страница 6: ...ting 3 high is switched on briefly 3 sec the unit will switch to the high setting for x minutes and then automatically return to the normal setting If any switch is operated during this lagging time t...

Страница 7: ...ort temperature 12 C 28 C 20 C P45 Current value of T1 outside air temperature Current C P46 Current value of T2 supply air temperature Current C P47 Current value of T3 return air temperature Current...

Страница 8: ...nce with alarm and malfunction alert P73 Malfunction before the most recent two Code in accordance with alarm and malfunction alert P74 Resetting malfunction s Set value to 1 and press OK on the displ...

Страница 9: ...EN 9 Menu P8 n a Analogue input values Submenu Description Minimum Maximum General Reset 850 n a 0 1 0 851 n a 0 1 0 852 n a 0 100 50 853 n a 0 99 0 854 n a 0 100 100 855 n a 0 1 0 856 n a 0 100...

Страница 10: ...settings The absent setting cannot be chosen with a normal 3 position switch For this the unit would need a ComfoSense Default settings air volume nL HL Absent Setting 15 15 Low Setting 35 40 Medium S...

Страница 11: ...the measurements of the exhaust valves together Determine the deviation to the expected setting P37 supply 3 Add all the measurements of the supply valves together Determine the deviation to the expe...

Страница 12: ...hed the ventilation setting will automatically return to the set value The default setting is 0 minutes The timer can be set from 0 minutes to 120 minutes or every minute in between 3 2 3 RFZ Wireless...

Страница 13: ...P50 When a fire place is present in the dwelling the open fire program must be activated This must be done in menu P50 The default setting is 0 open fire program not active The open fire program can a...

Страница 14: ...ower Supply 230V 10 single phase 50 60Hz cos f2 0 38 0 49 Power Maximal 1250 W 5 77 A Power Pre heater3 250 W 4 99 A General specifications Material Housing Coated Sheet Steel Material Interior EPP an...

Страница 15: ...how to replace the part Please check the pricelist of Zehnder for the article codes and prices of all available sets 2 1 8 3 4 5 9 6 4 7 2 Position Part 1 Set Filter Handles 2 Filterset G4 G4 1x 1x Fi...

Страница 16: ...16 EN 4 2 Dimension sketch 558 655 25 680 115 60 25 0 2 2 25 30 30 280 10 9 12 299 20 C i 125 87 86 194 140 140 144...

Страница 17: ...EN 17 Legend Code Description ODA Outdoor air SUP Supply air ETA Extract air EHA Exhaust air C Condensation drain 655 200 558 68 44 680 128 118 100 323 347 10 333 150 128 104 SUP ODA ETA EHA SUP...

Страница 18: ...Bl Black Y Yellow L3 Br Brown R Red Legend Code Decription Code Decription PH Pre heater T1 NTC Sensor Outdoor air M1 Exhaust motor T2 NTC Sensor Supply air M2 Supply motor T3 NTC Sensor Return air DI...

Страница 19: ...EN 19 Power cord Luxe version ComfoSense Position switch...

Страница 20: ...arrying out any work on the unit make sure the power is disconnected and cannot be inadvertently reconnected Always take ESD inhibiting measures when dealing with PCBs printed circuits boards such as...

Страница 21: ...t once every 4 years 1 Example valve Example grille 2 Example air duct 3 Remove the valves and or gratings Perform the following checks on the air ducts Pollution dirt and grease Air leakage loose joi...

Страница 22: ...p to remove the heat exchanger the bypass and the leakage tray Do not cut the strap Inspect and if necessary clean the heat exchanger Use a soft brush to clean the fins Use a vacuum cleaner or air gun...

Страница 23: ...e the fan impellors and temperature sensor do not get damaged 4 5 6 Push the two click fasteners outwards and pull the fan housing forwards Remove the 6 screws surrounding the fan housing and remove t...

Страница 24: ...ons to access the control PCB 1 2 3 Remove the heat exchanger as described in the cleaning instruction of the heat exchanger Remove the 4 screws of the electronics cover Remove the electronics cover W...

Страница 25: ...code which can appear on the display of the unit will also appear on the display of the ComfoSense Please refer to the malfunction overview below to find out the meaning of the relevant malfunction al...

Страница 26: ...ion chapter Yes 1 Remove the NTC sensor from the control PCB 2 Go to the next question No Reconnect the NTC sensor 4 Is the resistance of the NTC sensor correct See the specifications in the technical...

Страница 27: ...T1 correct See the specifications in the technical specification chapter Yes 1 Get the control PCB service set 2 Replace the control PCB No 1 Get the repair kit for the NTC sensor 2 Replace the NTC se...

Страница 28: ...unit 3 Remove the filter caps from the unit 4 Remove the dirty filters from the unit 5 Slide the clean new filters back into the unit The arrow on the filter must point downwards Cleaning Vacuum the f...

Страница 29: ...gs defective Replace the fan bearings Fan settings too high Change the fan settings Slurping noise U bend is empty U bend does not seal properly Reconnect the U bend Whistling noise An air gap somewhe...

Страница 30: ...30 EN...

Страница 31: ...EN 31...

Страница 32: ...Zehnder Group Nederland B V Lingenstraat 2 8028 PM Postbus 621 8000 AP Zwolle T 31 38 429 69 11 F 31 38 422 56 94 ventilatie zehnder nl www zehnder nl ZGNL Manual_40010844 V0517 EN Subject to change...

Отзывы: