6 - EN
2.1 P- menus for the user.
Menu P1 > Status of time programmes
Status
Submenu
Description
Activated
P11
Is menu P21 currently active?
Yes (1) / No (0)
P12
Is menu P22 currently active?
Yes (1) / No (0)
P13
Is menu P23 currently active?
Yes (1) / No (0)
P14
Is menu P24 currently active?
Yes (1) / No (0)
P15
Is menu P25 currently active?
Yes (1) / No (0)
P16
Is menu P26 currently active?
Yes (1) / No (0)
P17
Is the Summermode currently
active?
Yes (1) / No (0)
Menu P9 > Status of additional programmes
Status
Submenu Description
Activated
P90
Open fire programme active?
Yes (1) / No (0)
P91
Bypass open?
Yes (1) / No (0)
P94
n/a
Yes (1) / No (0)
P95
Frost protection or pre heater
active?
Yes (1) / No (0)
P97
Enthalpy programme active?
Yes (1) / No (0)
Menu P2 > Setting time delays
Time delay values
Submenu
Description
Minimum
Maximum
General
reset
P21
Only applies to systems
fitted with a bathroom
switch.
Delay timer for the bathroom switch (to switch to high position).
■
‘x‘ minutes after operating the bathroom switch,
the unit switches to the high setting.
0 Min.
15 Min.
0 Min.
P22
Only applies to systems
fitted with a bathroom
switch.
Overrun timer for the bathroom switch (to switch to normal
position).
■
‘x‘ minutes after operating the bathroom switch, the unit
switches back to the normal setting.
0 Min.
120 Min.
30 Min.
P23
Only applies to systems
fitted with a SA 1-3V, CCB,
or SA 0-3V switches.
Overrun timer for ventilation position 3 (using a hardwired
position switch).
■
If ventilation setting 3 (high) is switched on briefly
(< 3 sec), the unit will switch to the high setting for ‘x’ minutes
and then automatically return to the normal setting.
If any switch is operated during this lagging time the unit will
instantly revert to the ventilation position as set at that time.
0 Min.
120 Min.
0 Min.
P24
Filter warning
■
‘x’ weeks after cleaning or replacing the filters the “filter dirty”
alert will reappear.
10 weeks
26 weeks
16 weeks
P25
Only applies to systems
fitted with an RFZ switch.
Overrun timer for ventilation setting 3 (using
).
■
After pressing
briefly (< 2 sec.), the unit will switch to the
high setting for ‘x’ minutes and then
automatically returns to the normal setting.
If any switch is operated during this lagging time the unit will
instantly revert to the ventilation position as set at that time.
1 Min.
20 Min.
10 Min.
P26
Only applies to systems
fitted with an RFZ switch.
Overrun timer for ventilation setting 3 (using
).
■
After pressing
continously (> 2 sec.), the
unit will switch to the high setting for ‘x’ minutes and then
automatically returns to the normal setting.
If any switch is operated during this lagging time the unit will
instantly revert to the ventilation position as set at that time.
1 Min.
120 Min.
30 Min.
P27
Only applies to systems
fitted with a ComfoSense.
Time for the boost setting.
■
After turning on the PARTY TIMER on the ComfoSense, the
unit will switch to the high setting for ‘x’ minutes and then
automatically returns to the NORMAL setting.
If any switch is operated during this lagging time the unit will
instantly revert to the ventilation position as set at that time.
0 Min.
120 Min.
30 Min.