background image

4

5

Z23720

Z23720

When disposing of the heating appliance, comply with 

the regulations in force on the disposal of oil.

1.3 Overview of your radiator

This electrical appliance with circulating fluid is delivered ready to use.

It  is  plugged  and  filled  with  a  high-performance  thermal  mineral  oil  before

 

leaving the factory.

This  fluid  was  specially  designed  for  this  use  and  requires  no  special

 

maintenance.

As soon as the appliance is switched on, you will notice certain differences 

compared to a standard electric heating system:

-  the  electric  heating  element  heats  the  fluid,  which  gradually  and  naturally 

starts circulating in your appliance;

- the properties of the fluid are such that it takes approximately ten minutes for 

the radiator to reach its optimum surface temperature, depending on the model 

and the room temperature when the appliance is switched on;

- this principle also ensures consistent and sustained heating even when the 

element is no longer powered.

2. Installing your appliance

2.1 Warnings

The flexible cable supplied with your appliance is desi

-

gned to be connected to the mains via a junction box that 

must be placed behind the appliance, with no need for a 

plug. (Typically a fused spur)

In a kitchen or bathroom, the junction box must be 

positioned at least 25 cm from the floor.

The appliance must be installed as described in this 

document and in accordance with the applicable European 

and French standards, including CEI 60364.7.701 and NF 

C15-100, as well as the rules of good professional practice.

For other countries (apart from France), the appliance 

must be installed in accordance with standards in force and 

with rules of good professional practice in the country of 

use.

IMPORTANT

 The example shown only concerns a 

bathtub.  For  other  bathroom  fixtures,  please  consult 

your installer.

Содержание Bisque 4FE-40-106/F

Страница 1: ... F 24 32 40 46 24 33 38 45 26 34 45 53 67 475 475 475 475 575 575 575 575 675 675 675 675 675 642 826 1010 1148 550 734 826 964 504 642 826 964 1194 136 136 136 136 136 136 136 136 136 136 136 136 136 Weight kg Height 2mm Length 2 Depth 2mm 750 1000 1250 1500 750 1000 1250 1500 750 1000 1250 1500 2000 2559 3412 4265 5118 6824 2559 3412 4265 5118 2559 3412 4265 5118 Output Watts BTU Issue 10 0 Elec...

Страница 2: ...ed outside the bathroom Note for maintenance purposes cable outlets must remain accessible and cables must not be buried directly into walls FITTING INSTRUCTIONS Wall plugs 10mm Screws 7mm diameter x 60mm length Wall plugs 10mm Tape measure Spanner 13mm Socketdriver 10mm long reach Electric drill Masonry drill bit 10mm diameter Spirit level Tools Material Required Electric Classic Radiator A E B C...

Страница 3: ...lack of experience and knowledge if they have been given supervision or instruc tion concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision This appliance should be plugged or connected accor ding to rules and standards in application only by an auth...

Страница 4: ...nd the room temperature when the appliance is switched on this principle also ensures consistent and sustained heating even when the element is no longer powered 2 Installing your appliance 2 1 Warnings The flexible cable supplied with your appliance is desi gned to be connected to the mains via a junction box that must be placed behind the appliance with no need for a plug Typically a fused spur ...

Страница 5: ... wherever possible You will find a complete set of assembly instructions in your appliance s box 2 3 Connecting the appliance The technical specifications of your radiator are shown on its nameplate Please note these down before installing it and before requesting any after sales assistance When connecting the appliance to the mains you must observe the voltage indicated on the nameplate conventio...

Страница 6: ...blue or grey 3 Operating the electronic control 3 1 Description of control unit The ON Stand by button switches the regulator ON or puts it on standby when the device is on standby the display shows a flashing writing St by while when it is ON the display shows time and program in the Chrono mode or the temperature setting in the other modes The buzzer emits one beep after the transition from STAN...

Страница 7: ...p to the current setpoint temperature value the one shown in the Comfort mode FROST PROTECTION position Your radiator is set to ensure a minimum temperature of 7 C in your room to prevent any risk of frost All the pilot wire commands except STOP are disabled Chrono Pilot wire Comfort Eco Frost protection 3 3 Time setting and hourly programming Hold down the ON standby and Function buttons simultan...

Страница 8: ...d see table Setpoint temperature Pilote Wire signal Display Temperature COMFORT Setpoint temperature REDUCTION Setpoint temperature 3 5 ECO1 Setpoint temperature 1 C ECO2 Setpoint temperature 2 C FROST PROTECTION 7 C STOP Stop The STOP command is enabled in all modes except for the standby state If the STOP command was implemented outside of the mode Pilote Wire the icon blinks With the STOP comma...

Страница 9: ...e appliance s nameplate the sales reference for your appliance shown on your dated purchase invoice Guarantee See general conditions of sale for your country The heating body of your electric radiator is guaranteed against manufacturing defects for five 5 years from the date of purchase while the electrical components are guaranteed for two 2 years It complies with the EMC Directive 2004 108 EC re...