3. Description 

 
The  pumps  are  equipped  with  a  sturdy  alternating  current  motor;  the  sealing  of  the  pump  housing  to 
the  motor  is  executed  on  pump  side  using  a  mechanical  seal  and  on  motor  side  using  a  radial  shaft 
sealing ring.   
The current is connected using the 10 m long connecting cable with 230 V-50 Hz alternating current. 
 

-  The pump must be connected to a socket with earthing.  

-  Never carry the pump on the cable, never low it on cable into the water; 

never pull it      on cable out of the water. 

- If the power is not supplied obligatory via an earth leakage circuit breaker with 

maximum measured residual current 30 mA, the pump must be connected via a separate 
earth leakage circuit breaker to the socket. 

 
- The use of the pump at swimming pools and garden ponds and within their protection zones 

is only permitted if the plants located there are installed according to DIN VDE 0100/part 
702. It is forbidden to take a bath in the pool during operation of the pump. Ask you 
professional electrician.  

 

4. Installation and commissioning 

 
- Before commissioning of the pump, check it for possible external damages (e.g. transport 
damages), in order to prevent accidents with electrical power. 
 

  A minimum water level of 15 mm is necessary for a proper operation of the pump  
  (exhausts to 1 mm). 
 
If the pump shall be used in a cavity or a shaft the shaft/cavity must have a dimension of 300 x 300 x 
30 mm. The suction basket must not be blocked by sludge and/or media containing fibres.  
 
The pumping process starts with plugging the connector in the socket.  

 
 
-  In order to prevent damage to the shaft sealing, the pump must not run dry.  

 

5. Maintenance

 

 

 

-  Disconnect the power supply before carrying out any kind of work on the pump! 
 

Maintenance  contains  an  inspection  and  a  cleaning  of  the  pump  housing.  By  releasing  the  4  sheet 
metal screws (n° 1.32) on the lower side of the pum p, the bottom filter (n° 4.12) may be removed from 
the pump housing (n° 4.10). After cleaning, reassem ble these parts in reversed order and retighten the 
4 sheet metal screws.    

 

In case of a worn running wheel (e.g. due to abrasive media) a wear of the 
shaft sealing ring is also possible. The inspection of the shaft sealing ring 

and the motor as well as the replacement of the electric connecting cable may be effected 
by authorised after-sales services or by manufacturing factory only.     

 

 

 

 

 

Attention! 

Содержание FSP 330

Страница 1: ...Tauchpumpe Submersible pump Pompe submersible FSP 330 T Betriebsanleitung Operation Manual Manuel d utilisation...

Страница 2: ...Sicherheitshinweise 6 2 4 Sicherheitsbewu tes Arbeiten 6 2 5 Sicherheitshinweise f r den Betreiber Bediener 6 2 6 Sicherheitshinweise f r Wartungs Inspektions und Montagearbeiten 6 2 7 Eigenm chtiger...

Страница 3: ...ng entsprechen EG Niederspannungsrichtlinie 2014 35 EU EMV Richtlinie 2014 30 EU Maschinenrichtlinie 2006 42 EU Angewendete bereinstimmende Normen insbesondere EN 60335 1 2012 A11 2014 EN 60335 2 41 2...

Страница 4: ...en als Herstel ler zur Beratung gern zur Verf gung Bei Defekten oder Schadensf llen wenden Sie sich bitte an Ihren H ndler Hersteller ZEHNDER Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld F...

Страница 5: ...icherheitszeichen nach DIN 4844 W 9 bei Warnung vor elektrischer Spannung mit Sicherheitszeichen nach DIN 4844 W 8 besonders gekennzeichnet Bei Sicherheitshinweisen deren Nichtbeachtung Gefahren f r d...

Страница 6: ...r Personen und Um welt entsteht Gesetzliche Bestimmungen sind einzuhalten Gef hrdungen durch elektrische Energie sind auszuschlie en Einzelheiten hierzu siehe z B in den Vorschriften des VDE und der r...

Страница 7: ...berpr fen Sie die Pumpe vor Inbetriebnahme auf eventuelle u ere Besch digungen z B Transportsch den um Unf llen mit elektrischem Strom vorzubeugen F r ein einwandfreies Arbeiten der Pumpe ist ein Mind...

Страница 8: ...ausgenommen sind Sch den die auf unsachgem em Gebrauch oder auf Ver schlei Laufrad und Wellendichtung beruhen Au erdem erlischt der Garantieanspruch wenn Arbei ten au er den in Punkt 5 genannten an de...

Страница 9: ...2 Kugellager 608 900105 65 1 Federscheibe 800 014 100 1 Au engeh use FSP 100 200 110 1 Handgriff FSP 900113 1 120 1 Pumpengeh use FSP 900114 130 1 St tzring 100 250 140 1 Laufrad FSP 330 900117 160 1...

Страница 10: ...10 FSP 330...

Страница 11: ...case of non observance of the safety notes 14 2 4 Safety conscious way of working 15 2 5 Safety notes for the operator user 15 2 6 Safety notes concerning maintenance inspection and assembly works 15...

Страница 12: ...egulations in the respective valid version EC low voltage directive 2014 35 EU EMC directive 2014 30 EU Machinery directive 2006 42 EU Applied conform standards particularly EN 60335 1 2012 A11 2014 E...

Страница 13: ...ation also after the purchase In case of failures or damages please contact your retailer Manufacturer ZEHNDER Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Date of manufature The date of m...

Страница 14: ...danger to persons are specifically marked by the following general danger symbol Safety sign according to DIN 4844 W 9 The following symbol warns against dangers caused by voltage Safety sign accordin...

Страница 15: ...n Technology and the local energy suppliers 2 6 Safety notes concerning maintenance inspection and assembly works The operator must make sure that all maintenance inspection and assembly works are car...

Страница 16: ...k it for possible external damages e g transport damages in order to prevent accidents with electrical power A minimum water level of 15 mm is necessary for a proper operation of the pump exhausts to...

Страница 17: ...tributed to misuse or wear running wheel and shaft seal are excluded from warranty Furthermore the warranty claim expires if works excepting those under point 5 are effected on the pump We will assume...

Страница 18: ...2 Ball bearing 608 900105 65 1 Spring washer 800 014 100 1 Outer housing FSP 100 200 110 1 Handle FSP 900113 1 120 1 Pump housing FSP 900114 130 1 Support ring 100 250 140 1 Running wheel FSP 330 900...

Страница 19: ...19 FSP 330...

Страница 20: ...t 24 2 4 Travailler dans le respect des r gles de s curit 24 2 5 Consignes de s curit pour l op rateur l utilisateur 24 2 6 Consignes de s curit pour les travaux de maintenance inspection et montage 2...

Страница 21: ...ntes suivantes Directive 2014 35 EU relative la basse tension Directive 2014 30 EU relative la comptabilit lectromagn tique Directive 2006 42 EU relative aux machines Normes harmonis es appliqu es pri...

Страница 22: ...n cas de d faillances ou de dommages veuillez vous adresser votre revendeur sp cialis Fabricant ZEHNDER Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Allemagne Date de fabrication La date d...

Страница 23: ...ilisation Les consignes de s curit contenues dans ce manuel d utilisation pouvant entra ner des risques pour les personnes en cas de non respect sont marqu es et mises en valeur par un symbole g n ral...

Страница 24: ...ergie 2 6 Consignes de s curit pour les travaux de maintenance inspection et montage L exploitant doit s assurer que tous les travaux d entretien d inspection et de montage sont r alis s par du person...

Страница 25: ...pompe par ex des dommages dus au transport afin de pr venir les accidents et les lectrocutions Un niveau d eau minimal de 10 mm est requis pour un fonctionnement optimal de la pompe aspiration jusqu 1...

Страница 26: ...n non conforme et l usure rotor et bague d tanch it En outre tout recours en garantie est annul lorsque des travaux ont t r alis s sur la pompe sans l accord du fabricant Les dommages survenus la suit...

Страница 27: ...ment billes 608 900105 65 1 Rondelle lastique 800 014 100 1 Carter ext rieur FSP 100 200 110 1 Poign e FSP 900113 1 120 1 Carter pompe FSP 900114 130 1 Bague d appui 100 250 140 1 Roue FSP 330 900117...

Страница 28: ...28 FSP 330...

Отзывы: