background image

14 

 
 
This warranty does not cover damage cause by improper use or wear and tear (mechanical seal, diaphragm, at booster kits). Also, there will 
be no warranty given in case of unauthorised repair of the pump. Consequential damages caused by failing of the pump are not covered by 
the manufacturer. 
 

 

7. Disposal 

 

For EU-countries only. Do not dispose the pump into the domestic waste. 
In accordance to the European guideline 2002/96/EG concerning electrical and electronic equipment and implanting into 
national law used electrical tools have to be collected separately and supplied to an environmentally compatible recycling. 

 
 
 

8. Technical Modification 

 

… without prior notice. 
 

9. Fault, possible reason and recovery 

 

Faults Possible 

reasons 

Recovery 

1. Pump does not suck in 

Pump housing is not filled with water 

Fill the pump chamber with water 

Suction connection not tight 
Pump sucks in air 

Thread connections tight with Teflon 
coated sealing tape or hemp 
Use a special coupling 

Suction height to long (max. 8.5m) 

Reduce the sucking height 

Suction hose is shrinked 

Use a spiral hose 

Motor protector activated overheating, 
blocking, voltage fault or any other error 

Check, consult the customer service 

2. Pressure decrease suddenly 

Foot valve with sucking side is missing or 
leaky 

Install foot valve, check or clean 

3. Pump switches on/off in short 
intervals 

Diaphragm in vessel damaged 
(Leakiness at the air valve) 

Renew the diaphragm (expendable part) 

To less pre- pressure in diaphragm vessel 

Produce the necessary air pressure (see 
ch. 4) 

Pressure switch set wrong 
 

Pressure switch justify so that a 
difference of 2bar between switch on and 
switch off pressure (see ch. 4) 

Foot valve with sucking side is missing or 
leaky 

Clean and reinstall foot valve 

Pressure switch damaged 

Renew pressure switch 

4. Pump does not switch off 

Pump will not exceed switch off pressure. 
 

Check pre- filter and pump hydraulic 
(impeller) of contamination and if 
necessary clean 

Switch off pressure at the pressure switch 
adjusted to high 

Decrease the switch off pressure 

Pressure switch defect 

Replace the pressure switch 

5. Pump switches off 

Motor overheated, triggering of the 
thermal motor protection 

Motor switches on after cooling down 
automatically 

Power failure 

Check power supply, fuse 

6. Leakage between pump housing and 
motor 
 
 
 
 
 

Mechanical seal damaged 

Renew mechanical seal 

Possible frost damage 

In most instances the pump is damaged 
beyond repair 
a) Motor flange is warped 
b) Sealing support deformed 
c) Cleat of the end shield demolished 

 

Before sending back a pump or a booster- kit, check the above mentioned items, please. 

 
Back sending to the manufacturer Carriage paid with original wrapping: 
 
Zehnder- Pumpen GmbH 
Zwönitzer Str. 19 
D - 08344 Grünhain-Beierfeld 
 
Please tell us the failure mode of the unit, as this will reduce the waiting time and also put the proof of purchase inside. 
 

GB

Содержание EP 11-3

Страница 1: ...k Garden pumps Booster units Pompe de jardin Usine hydraulique de maison Baureihe Series S rie EP EPA Betriebsanleitung Operating Instructions Manuel d utilisation GB D EP 11 3 EPA 11 3 EPA 11 3E EP 1...

Страница 2: ...srichtlinie 93 68 EWG Anhang I im Sinne der EMV Richtlinie 92 31 EWG und 93 68 EWG im Sinn der Maschinenrichtlinie 2006 42 2009 Hiermit erkl ren wir die ZEHNDER Pumpen GmbH Zw nitzer Stra e 19 08344 G...

Страница 3: ...en GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Baugr en EP 11 3 EPA 11 3 EPA 11 3E EP 15 3 EPA 15 3 EPA 15 3E Stand der Betriebsanleitung Februar 2009 1 2 Anfragen und Bestellungen Anfragen und...

Страница 4: ...t dieses zu schulen und zu unterweisen Dies kann falls erforderlich im Auftrag des Betreibers der Pumpen durch den Hersteller Lieferant erfolgen Weiterhin ist durch den Betreiber sicherzustellen dass...

Страница 5: ...u kabels mit 230 V 50 Hz Wechselstrom Die Pumpe muss an eine Steckdose mit Erdung angeschlossen werden Pumpe nicht am Kabel ziehen oder tragen Die Pumpe darf mit einem besch digten Kabel nicht in Betr...

Страница 6: ...maler F rderh he der Pumpe laut Typenschild minus Ansaugh he Der Ausschaltdruck sollte mindestens 5 m 0 5 bar unter dem maximal erreichbaren Druck der Pumpe liegen Nach dem Ver ndern des Einschaltdruc...

Страница 7: ...abdichten Schnellkupplungen z B Geka mit Nachstellring zum Anpressen verwenden Saugh he zu gro max 8 5 m Saugh he verringern Saugschlauch zieht sich zusammen Spiralsaugschlauch verwenden aktivierter...

Страница 8: ...cksendungen an den Hersteller bitte nur frei und in der Originalverpackung an Zehnder Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Zur Verk rzung der Reparaturzeit benennen Sie uns bitte...

Страница 9: ...aration of Conformity In accordance with EEC low voltage specifications 93 68 EWG app I In accordance with EMV Specifications 92 31 EWG und 93 68 EWG In accordance with 2006 42 EG We the following ZEH...

Страница 10: ...s and Ordering For queries and orders please contact your authorised retail trader 1 3 Technical data Typ EP 11 3 EPA 11 3 EPA 11 3E EP 15 3 EPA 15 3 EPA 15 3E Power P1 600 Watt 1000 Watt Voltage 230...

Страница 11: ...to non compliance with safety advice Ignoring of safety instructions can lead to danger of personnel and to the environment as well as causing possible damage to the equipment Non compliance with saf...

Страница 12: ...al protection this circuit breaker must trip out when earth fault current exceeds 30mA The pump must not drop in water and also not submersible Any operation of the pump next to a swimming pool or gar...

Страница 13: ...e diaphragm vessel The air pressure must be approx 0 2 to 0 3 bar less than starting pressure of the unit Procedure Disconnect the power supply Open the tap that the system will be vented Remove the b...

Страница 14: ...n short intervals Diaphragm in vessel damaged Leakiness at the air valve Renew the diaphragm expendable part To less pre pressure in diaphragm vessel Produce the necessary air pressure see ch 4 Pressu...

Страница 15: ...t Dans le sens de la directive de basse tension EG 93 68 EWG annexe I Dans le sens la directive EMV 92 31 EWG et 93 68 EWG Dans le sens la directive 2006 42 EG Nous d clarons nous ZEHNDER Pompes SARL...

Страница 16: ...es de construction EP 11 3 EPA 11 3 EPA 11 3E EP 15 3 EPA 15 3 EPA 15 3E Etat du manuel d utilisation 02 2009 1 2 Demandes et commandes Veuillez adresser vos demandes et commandes votre commer ant de...

Страница 17: ...s Une telle formation peut avoir lieu au besoin sur ordre de l op rateur des pompes par le fabricant fournisseur L op rateur doit encore garantir que le contenu du manuel est pleinement compris par le...

Страница 18: ...imentation en courant ne devait pas s effectuer obligatoirement par un Interrupteur de protection de personnes FI avec au maximum 30 mA d lectricit d erreur de mesure la pompe doit tre attach e sur un...

Страница 19: ...aut contr ler dans tous les cas la pression de d clenchement On Off ATTENTION La pression de d clenchement ne doit en aucun cas tre sup rieure la pression maximale atteinte de la pompe sinon la pompe...

Страница 20: ...nt exclues Les d rangements qui ne peuvent pas tre facilement r par s ne devraient tre limin s que par le service clients de Zender ou par des entreprises sp cialis es autoris es Les dommages qui sont...

Страница 21: ...viron 2 bar voir point 4 Valve de pied perm able et ou pas existante Nettoyez resp installez la valve de pied Interrupteur pression en panne Renouvelez l interrupteur pression 4 La pompe ne d clenche...

Страница 22: ...0 Schraube M6x20 mit Mutter und Unterlegscheibe Screw M6x20 with nut M6 and washer Vis M6x20 avec crou et rondelle 20 1 3 Stopfen G mit O Ring Plug G with O ring Bouchon G avec joint torique 21 4 Bund...

Страница 23: ...23 Ersatzteilzeichnung Spare parts drawing Dessin des pi ces de rechange...

Страница 24: ...24 ______________________________________________________________________________________________________ 2007 ZEHNDER Pumpen GmbH...

Отзывы: