- 8 -
23. MONITORING
Connect
programmer
to
PCDI
and wait few seconds for activation of
programmer.
Fist
information displayed on the
programmer
is software version.
With
programmer
you can watch revs, calculated advance ignition angle, PV valve position
and TPS position.
Information!
You can connect or disconnect
PCDI
unit from
programmer
any time you want, without any
harm. It is not important, if motor running or not and if power supply is connected or not.
Important!
Do not use too much force when connecting or disconnecting
programmer
unit!
24. ERROR
REPORTS
Two errors can be displayed:
Program Memory Error
- when program memory is corrupted. With this error present,
function of program could be faulty.
EEPROM Error
- when eeprom memory is corrupted. All programmable data are stored in
eeprom memory (curve, rev limit...). With this error present, function of program could be
faulty.
You must check all your settings and correct changed.
PVerror 1
– position sensor error, or servo motor disconnected
PVerror 2 –
servo motor error (short connection)