background image

 

 

- 1 -

 

www.zeeltronic.com 
[email protected] 
 
updated 21.06.2008 
program version: 000.180608 
 

USER MANUAL  

PCDI-11V 

PROGRAMMABLE CDI IGNITION AND PV CONTROLLER 

 
 

 

TECHNICAL DATA 
 
Limit values: 
- minimum revs 

200 RPM 

- maximum revs 

20000 RPM 

- minimum supply voltage 

8 Volts 

- maximum supply voltage 

16 Volts 

- max. supply voltage for 1 minute 

35 Volts 

- current draw  

                     25 mAmp 

- maximum continuous current for shift light output 

1 Amp  

- peak current for shift light output  

5 Amp 

 
Circuit is protected against reverse supply voltage (wrong connection). 
 
Features: 
- CDI charged from hi voltage charging coils (generator) 
- programmable ignition map (3D interpolated) 
- store and load function for 2 ignition maps 
- one input for magnetic pickup 
- TPS input (ignition map is 3D interpolated above TPS33%) 
- external switch for changing ignition map while riding 
- shift light output 
- quick shift (shift kill) 
- tachometer output 
- advance/retard whole ignition curve 
- three stage rev limit (retard timing, reduced spark, spark off) 
- signal delay compensation 
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...) 
- programmable power valve actuation 
- store and load function for 5 PV curves 
- programmable PV deviation 
- programmable max close and max open positions 
- self PV test on power-up 
- PV error detecting (position sensor failure, servo motor failure) 

Содержание PCDI-11V

Страница 1: ...m hi voltage charging coils generator programmable ignition map 3D interpolated store and load function for 2 ignition maps one input for magnetic pickup TPS input ignition map is 3D interpolated abov...

Страница 2: ...U Load Ign Curve load previously saved ignition curve set from 1 to 2 Save Ign Curve save new ignition curve set from 1 to 2 Ignition Curve ignition curve parameters submenu Advance advance retard who...

Страница 3: ...ch between ignition curves but also calculate timing between programmed curves for all TPS positions above 33 From 0 to 33 TPS is used only one ignition curve Enter menu and move to Ignition Curve wit...

Страница 4: ...ed Enter menu and move to Advance with pressing or and then press enter Now you can set advance with pressing or in 0 1deg steps and then press enter 7 Set SHIFT LIGHT Enter menu and move to Shift Lig...

Страница 5: ...TPS close 0 with pressing or and then press enter Leave throttle at close position and confirm calibrating with pressing enter or exit calibration with pressing Displayed number should be between 0 a...

Страница 6: ...ou make any changes to valve curve it is automatically saved to 0 position Then you can save it to any other position number from 1 to 5 17 1 Change Number of Curve Points Move to Nr of Points with pr...

Страница 7: ...and then press enter Now you can set open position with pressing or and then press enter Max open position is when curve is set to 100 This open position can be moved to any desired position For RZ35...

Страница 8: ...nd if power supply is connected or not Important Do not use too much force when connecting or disconnecting programmer unit 24 ERROR REPORTS Two errors can be displayed Program Memory Error when progr...

Отзывы: