- 2 -
- easy and fast programming on the field, via hand held programmer
- programming while machine running - you can immediately see effects
- monitoring of rev's, TPS position, ignition and PV angle, via LCD(hand held programmer)
- fast processing for high accuracy - delays from 1us
1.
HOW TO ENTER MENU
PCDI
must be connected to power supply. Connect
programmer
to
PCDI
and wait few
seconds for activation of
programmer
and then press enter. With pressing + or - you can
move through menu and select with pressing enter .
Exit menu with selecting
Exit.
2.
MENU ORGANISATION
Set Ign.
- set ignition parameters submenu
Set PV
- set PV parameters submenu
Exit
2.1.
SET IGNITION PARAMETERS SUBMENU
Load Ign. Curve
- load previously saved ignition curve set (from #1 to #2)
Save Ign. Curve
- save new ignition curve set (from #1 to #2)
Ignition Curve
- ignition curve parameters submenu
Advance
- advance/retard whole ignition curve
Shift Light
- shift light
Shift Kill Time
- shift kill time
Rev Limit
- rev limit
Static Angle
- static angle (stator position)
Compensation
- signal delay compensation (from pickup to spark plug)
TPS close [0%]
- calibrating TPS close position
TPS open [100%]
- calibrating TPS open position
Remote SW
- activating/deactivating external switch
Exit
2.2.
SET PV PARAMETERS SUBMENU
Load PV Curve
- load previously saved curve (from #1 to #5)
Save PV Curve
- save new curve (from #1 to #5)
Set PV Curve
- valve curve parameters submenu
Dev-
- deviation of valve position
Close Position
- max close valve position
Open Position
- max open valve position
PV test
- valve position test
Exit