- 4 -

5.1. 

Set NUMBER OF IGNITION CURVE POINTS

 

 
Move to 

Nr. of Points

 with pressing  +  or  -  and then press  enter  . 

Now you can select number of ignition points, with pressing  +  or  -  and then press  enter  . 
 

 
5.2. 

Set PARAMETERS OF IGNITION CURVE POINT 

 
Move to point you want to change, with pressing  +  or  -  and then press  enter  . 
Now you can change rev point with pressing  +  or  -  (in 100 rpm steps) and then press   

enter  . 

Now you can change advance angle with pressing  +  or  -  (in 0.1deg steps) and then press  

enter  .  

  

 
6. Set 

ADVANCE 

 
With this setting is possible to advance or retard whole ignition curve. When setting is 
positive then ignition curve is advanced and when setting is negative than ignition curve is 
retarded. With 

Advance

 

0.0deg

, ignition curve is unchanged.  

Enter menu and move to 

Advance 

 with pressing  +  or  -  and then press  enter  . 

Now you can set advance with pressing  +  or  -  (in 0.1deg steps) and then press  enter  . 

 
 
7. 

Set SHIFT LIGHT 

 
Enter menu and move to 

Shift Light 

with pressing  +  or  -  and then press  enter  . 

Now you can change rev point with pressing  +  or  -  (in 100 rpm steps) and then press    

enter  . 

 
 
8. 

Set SHIFT KILL TIME 

 
Enter menu and move to 

Shift Kill Time 

with pressing  +  or  -  and then press  enter  . 

Now you can change kill time with pressing  +  or  -  (in 10 ms steps) and then press  enter  . 
 

 
9. 

Set REV LIMIT 

 
Enter menu and move to 

Rev Limit 

with pressing  +  or  -  and then press  enter  . 

Now you can change rev limit with pressing  +  or  -  (in 100 rpm steps) and then press    

enter  . 

 
 

10. 

Set STATIC ANGLE 

 
Enter menu and move to 

Static Angle 

 with pressing  +  or  -  and then press  enter  . 

Now you can set static angle with pressing  +  or  -  (in 0.1deg steps) and then press  enter  . 
More information's about static angle you can find in section 22. 

Содержание PCDI-11V

Страница 1: ...m hi voltage charging coils generator programmable ignition map 3D interpolated store and load function for 2 ignition maps one input for magnetic pickup TPS input ignition map is 3D interpolated abov...

Страница 2: ...U Load Ign Curve load previously saved ignition curve set from 1 to 2 Save Ign Curve save new ignition curve set from 1 to 2 Ignition Curve ignition curve parameters submenu Advance advance retard who...

Страница 3: ...ch between ignition curves but also calculate timing between programmed curves for all TPS positions above 33 From 0 to 33 TPS is used only one ignition curve Enter menu and move to Ignition Curve wit...

Страница 4: ...ed Enter menu and move to Advance with pressing or and then press enter Now you can set advance with pressing or in 0 1deg steps and then press enter 7 Set SHIFT LIGHT Enter menu and move to Shift Lig...

Страница 5: ...TPS close 0 with pressing or and then press enter Leave throttle at close position and confirm calibrating with pressing enter or exit calibration with pressing Displayed number should be between 0 a...

Страница 6: ...ou make any changes to valve curve it is automatically saved to 0 position Then you can save it to any other position number from 1 to 5 17 1 Change Number of Curve Points Move to Nr of Points with pr...

Страница 7: ...and then press enter Now you can set open position with pressing or and then press enter Max open position is when curve is set to 100 This open position can be moved to any desired position For RZ35...

Страница 8: ...nd if power supply is connected or not Important Do not use too much force when connecting or disconnecting programmer unit 24 ERROR REPORTS Two errors can be displayed Program Memory Error when progr...

Отзывы: