Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
Manual of 07/06/2019 Rev. 1.1 “User Manual for 20K-33KTL”
ID66
UnrecoverBusOVP
The bus voltage is too
high and has caused
an irreparable fault.
present. If this is not the case, contact
Technical Support.
ID67
UnrecoverIacRmsUnbalance
The grid current is
not balanced and has
caused an irreparable
fault.
ID68
UnrecoverIpvUnbalance
The input current is
not balanced and has
caused an irreparable
fault.
ID69
UnrecoverVbusUnbalance
The bus voltage is not
balanced and has
caused an irreparable
fault.
ID70
UnrecoverOCPInstant
The grid current is
too high and has
caused an irreparable
fault.
ID71
UnrecoverPvConfigSetWrong
Incorrect input mode
Check the configuration of the input
mode (parallel mode / independent
mode) of the inverter, as indicated in
Section 6.3 (C) “6. Input Mode” of this
user manual. If it is not correct,
change it according to Section 6.3 (A).
ID72-ID73
Reserved
Reserved
Reserved
ID74
UnrecoverIPVInstant
The input current is
too high and has
caused an irreparable
fault.
ID74-ID77 are internal faults of the
inverter; turn off the “DC switch”, wait
5 minutes and then turn it back on
again. Check that the fault is no longer
present. If this is not the case, contact
Technical Support.
ID75
UnrecoverWRITEEEPROM
The E E P R O M
cannot be recovered.
ID76
UnrecoverREADEEPROM
The E E P R O M
cannot be recovered.
ID77
UnrecoverRelayFail
The relay has
generated a
permanent fault.
ID78-ID80
Reserved
Reserved
Reserved