49/50
User Manual for HYD 3-6 kw ES Hybrid Inverter - Rev. 1.1 del 13/06/2019
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
ID101
BatSCD
Short-circuit discharge
protection
if the problem has been resolved.
If the fault occurs frequently, contact ZCS
Technical Support.
ID102
BatOV
Battery overvoltage
protection
ID103
BatUV
Battery undervoltage
protection
ID104
BatOTD
Battery
overtemperature
protection while
discharging
Make sure that the battery is in a well-
ventilated place.
Try to decrease the maximum discharge (A)
and/or maximum charge (A) to see if the
problem is fixed.
ID105
BatOTC
Battery
overtemperature
protection while
charging
ID106
BatUTD
Battery low
temperature protection
while discharging
Try to increase the ambient temperature in the
battery location.
ID107
BatUTC
Battery low
temperature protection
while charging