35/50
User Manual for HYD 3-6 kw ES Hybrid Inverter - Rev. 1.1 del 13/06/2019
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
27.S1: 228V 408ms
↓
Press “Down”
27.S2 threshold 92V 200ms
↓
Press “Down”
27.S2: 227V 205ms
↓
Press “Down”
81>.S1 threshold 50.5Hz 100ms
↓
Press “Down”
81>.S1 49.9Hz 103ms
↓
Press “Down”
81>.S2 threshold 51.5Hz 100ms
↓
Press “Down”
81>.S2 49.9Hz 107ms
↓
Press “Down”
81<.S1 threshold 49.5Hz 100ms
↓
Press “Down”
81<.S1 50.0Hz 105ms
↓
Press “Down”
81<.S2 threshold 47.5Hz 100ms
↓
Press “Down”
81<.S2 50.1Hz 107ms
2)
STD Self-test
Select “2. STD self-test,” then press “OK” to start the STD self-test.
The test procedure is the same as the Fast Self-Test, but much longer.
3)
PF Time Setting
Select “3. PF Time Setting”, then press “OK”. The following will appear on the screen:
Set:
*.
*** s
Press “Up” or “Down” to change the first digit, press “OK” to move to the next one. After changing all the digits,
press “OK”.
4)
QV Time Setting
Select “4. QV Time Setting”, then press “OK”. The following will appear on the screen:
Set: ** s