28/50
User Manual for HYD 3-6 kw ES Hybrid Inverter - Rev. 1.1 del 13/06/2019
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
3)
Select type of battery
MENU
Compatible batteries
1.PYLON
PYLONTECH US2000 PLUS / US2000B
2. DARFON
DARFON 14S31P ESS
3.DEFAULT
LEAD-ACID / LEAD-CRYSTAL / AQUION batteries
4. Lithium
All batteries that comply with ZCS’s BMS CAN communication protocol (Tawaki Maui
and Weco ReSU 4K4).
5. Alpha. ESS
M48112-P / SMILE-BAT
6. SOLTARO
SL-3KWH/ SL-1KWH
Press “Up” or “Down” to select the battery type, press “OK”” to complete the selection.
If type “1. PYLON”, “2. DARFON”, “4. Lithium”, “5. Alpha. ESS” or “6. SOLTARO” batteries are used then
congratulations! The initial configuration of the inverter is complete. Press “OK” to enter the main interface.
If different batteries are used, select type “3. DEFAULT” to enter additional information about the batteries
used. In this case, contact the ZCS Technical Support.