User Manual 3PH HYD5000-HYD20000-ZSS
Rev. 1.1 16/03/2021
Identification: MD-AL-GI-00
Rev. 1. of 16/03/2021 - Application: GID
76/138
In case of
double battery tower (Pylontech, WeCo)
set the inputs:
•
Input channel 1 → BAT input 1
•
Input channel 2 → BAT input 2
For independent strings, set:
•
Input channel 3 → PV input 1
•
Input channel 4 → PV input 2
For parallel strings, set:
•
Input channel 3 → PV input 1
•
Input channel 4 → PV input 1
7.2.5.
Setting of battery parameters
Single
Pylontech
battery
tower
Single WeCo
battery
tower
Double PYLON/WECO battery
tower
Battery identification
Battery 1
Battery 1
Battery 1
Battery 2
1.Battery Type
PYLON
WECO
PYLON/WECO
PYLON/WECO
2.Battery Address
00
00
00
01
3.Max Charge (A)
25.00
50.00
25.00
25.00
4.Max Discharge (A)
25.00
50.00
25.00
25.00
5.Discharge Depth
max 90%
max 90%
max 90%
max 90%
6.Save
ok
ok
ok
ok
Item
Default state
Energy Storage Mode
Self-use mode
EPS Mode
Disable
Anti Reflux
Disable