Solo documento principale.
Ident
ific
at
ion:
M
D
-AL
-GI
-00
R
ev
. 4
.0
of
31.
01.
18
-
Appl
ic
at
ion
: G
ID
Pile Reg. IT12110P00002965 -
Share Capital € 100,000.00 fully paid up
AR Bus. Reg. no. 03225010481
– AR REA no. - 94189
Certified Company ISO 9001 - Certificate no. 9151 - CNS0 - IT-17778
Zucchetti Centro Sistemi S.p.A. - Green Innovation Division
Via Lungarno, 248 - 52028 Terranuova Bracciolini - Arezzo, Italy
tel. +39 055 91971 - fax. +39 055 9197515
[email protected] - [email protected] -
zcsazzurro.com
Manual of 25/08/2020 Rev. 1.2 “User Manual 7000-BE-24”
21/43
1)
Insert the exposed wires into the OT terminal and crimp them using a crimping tool, as shown in
Figure 10.
Note 1
: L3 is the length between the insulation layer of the ground cable and the crimped part. L4 is the
distance between the crimped part and the conductor wires protruding from the crimped part.
Note 2
: The cavity formed after the conductor has been crimped must completely wrap the conductor
wires. The core of the wire must be in close contact with the terminal.
Figure 10 – Preparing the ground cable
(2)
2)
Install the crimped OT terminal and flat washer by inserting the M5 screw into the hole located on
the lower bar of the charging station, as shown in the figure; tighten the screw to a torque of 3 Nm
using a screwdriver.
Figure 11 - Connecting the ground terminal