4.9
Reset NSS to Default Settings
Section 4.7 details how to access the Reset submenu from the NSS LCD Main Menu. The Reset Menu includes
a number of options and the associated default values are detailed below:
4.9.1
Admin Passwd
Select the “Admin Passwd” option to ERASE the current Admin Password. Once this has been done a new
Admin Password may be set as described in section 2.7.3.1.
4.9.2
Config Reset
Selecting the “Config reset” option from the
RESET MENU
will reset in ALL user-configured settings being reset
to their default values. This includes the following:
IP address
(reset to 192.168.0.201)
net mask
(reset to 255.255.255.0)
default gateway
(reset to “none”)
TCP Port
(reset to 5100)
Trace level
(reset to “default”)
4.9.3
Factory Reset
The “Factory Reset” option is only available to the HSM Manufacturer and is used to deleting all database files
including the logs, as well as the settings that are reset by “Config reset”.