27) PUMP DECELERATION DELAY
In seconds. Set the deceleration ramp for the pump motor.
28) MAX SPEED LIFT
From 0% to 100%. It limits the maximum speed of the lift function. Percentage
of the maximum voltage applied to the pump motor for the lift function. If it is set
0% the motor does not work when the lift request is ON.
29) LIFT CUTBACK
From 0% to 100%. It reduces the maximum speed of the lift function when the
pump cutback switch, CAN#6 connector, is active.
When set to a percentage which is higher than MAX SPEED LIFT, the pump
speed reduction is ineffective.
If set 0% the motor is stopped when the pump cutback switch is ON.
30) 1
ST
PUMP SPEED
From 0% to 100%. It limits the speed of the 1ST function. Percentage of the
voltage applied to the pump motor for the 1ST function. If it is set 0% the motor
don’t work when the 1ST request is ON.
31) 2
ND
PUMP SPEED
From 0% to 100%. It limits the speed of the 2ND function. Percentage of the
voltage applied to the pump motor for the 2ND function. If it is set 0% the motor
don’t work when the 2ND request is ON.
32) DESCENT SPEED
From 0% to 100%. It limits the maximum speed of the descent function.
Percentage of the maximum voltage applied to the pump motor for the descent
function. If it is set 0% the motor don’t work when the descent request is ON.
33) PUMP CREEP SPEED
Percentage. It sets the minimum speed (percentage of voltage applied) for the
pump motor. Percentage of the maximum voltage applied to the pump motor
when the Lift SW is closed.
34) PUMP COMPENSAT.
From 0% to 100% This parameter sets the voltage compensation (
∆
V) applied
to the motor when the proportional lifting function is active. The value of this
∆
V
applied to the motor is a function of the motor current. Aim of this function is to
reduce, as for as possible, the speed difference between the truck loaded and
unloaded.
35) HYD SPEED FINE
Percentage. Fine adjustment of the pump motor steering function speed.
36) HYDRO COMPENSATION
Percentage. Adjustment of the compensation function when the pump motor
steering function is active.
37) MIN EVP
0 to 100. This parameter determines the minimum current applied on the EVP
when the position of the potentiometer is at the minimum. This parameter is not
effective if the EVP is programmed like a On/Off valve.
Содержание ACEX
Страница 27: ...AFCZP0BC COMBIACX ACEX User Manual Page 27 81 8 DRAWINGS 8 1 Mechanical drawing COMBIACX...
Страница 28: ...Page 28 81 AFCZP0BC COMBIACX ACEX User Manual 8 2 Mechanical drawing ACEX...
Страница 29: ...AFCZP0BC COMBIACX ACEX User Manual Page 29 81 8 3 Connection drawing COMBIACX...
Страница 30: ...Page 30 81 AFCZP0BC COMBIACX ACEX User Manual 8 4 Connection drawing ACEX...
Страница 35: ...AFCZP0BC COMBIACX ACEX User Manual Page 35 81 10 3Description of the console menu 10 3 1 COMBIACX ACEX Menu...