Securing the appliance to the cabinet
A
B
Electrical installation
The manufacturer is not responsible
if you do not follow the safety
precautions from the Safety
chapters.
This appliance is supplied only with a main
cable.
Cable
Cable types applicable for installation or
replacement: H07 RN-F, H05 RN-F, H05 RRF,
H05 VV-F, H05 V2V2-F (T90), H05 BB-F.
For the section of the cable refer to the total
power on the rating plate and to the table:
Total power (W)
Section of the ca-
ble (mm²)
maximum 1380
3 x 0.75
maximum 2300
3 x 1
maximum 3680
3 x 1.5
The earth cord (green / yellow cable) must be 2
cm longer than phase and neutral cables (blue
and brown cables).