This appliance is supplied only with a main
cable.
Cable
Cable types applicable for installation or
replacement:
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total
power on the rating plate. You can also refer to
the table:
Total power (W)
Section of the ca-
ble (mm²)
maximum 1380
3 x 0.75
Total power (W)
Section of the ca-
ble (mm²)
maximum 2300
3 x 1
maximum 3680
3 x 1.5
The earth cord (green / yellow cable) must be 2
cm longer than phase and neutral cables (blue
and brown cables).
Technical data
Technical data
TOTAL POWER:
Electric:
0.05 kW
Gas original:
G20 (2H) 20 mbar = 2.7 kW
Gas replacement:
G30 (3+) 28-30 mbar = 2.7 kW
G31 (3+) 37 mbar = 2.7 kW
Electric supply:
220 - 240 V ~ 50 / 60 Hz
Appliance category:
II2H3+
Gas connection:
G 1/2"
Appliance class:
3
Gas oven burner
Gas type
NOMINAL
GAS POW-
ER (kW)
NOMINAL
GAS FLOW
(g/h)
Reduced
gas power
(kW)
BY-PASS
NEEDLE
(1/100
mm)
INJECTOR
MARK
(1/100
mm)
G20 (2H) 20 mbar
2.7
-
0.7
Reg.
G30 (3+) 28-30 mbar 2.7
196
0.7
43
80
G31 (3+) 37 mbar
2.7
193
0.7
43
80
www.zanussi.com