BYPASS DIAMETERS
BURNER
Ø BYPASS 1/100 mm
Auxiliary
29
Semi-rapid
32
Rapid
55
Triple Crown
67
Oven
54
Grill
59
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER kW
REDUCED POWER kW
INJECTOR MARK 1/100
mm
Triple Crown
3.8
1.8
146
Rapid
2.9
1.1
119
Semi-rapid
1.85
0.45
96
Auxiliary
0.95
0.35
70
Oven
3.6
1.5
126
Grill
2.5
1.6
111
GAS BURNERS FOR LPG G30 28-30 mbar
BURNER
NORMAL POW-
ER kW
GAS RATE g/h
REDUCED POWER
kW
INJECTOR MARK
1/100 mm
Triple Crown
4.0
290.9
1.8
101o
Rapid
3.0
218.1
1.1
88
Semi-rapid
1.85
134.5
0.43
71
Auxiliary
0.95
69.1
0.35
50
Oven
3.6
261.8
1.5
90
Grill
2.5
181.8
1.6
80
GAS CONNECTION
WARNING! Before you connect the
gas, disconnect the appliance from the
electricity supply or switch off the fuse
in the fuse box. Close the primary
valve of the gas supply.
The gas pipe in the appliance has two endings. You
can connect the gas supply to either one of them.
The pipe that is not used must be clogged with the
pipe closer, which added to the appliance.
Use a fixed connections or use a flexible stainless
steel pipes in compliance with the regulation in
force. If you use flexible metallic pipes, make sure
22