Z3-DME-20 User Instructions
DOC-USR-0180-05
___________________________________________________________________________________________
Z3 Technology, LLC
♦
100 N 8
th
ST, STE 250
♦
Lincoln, NE 68508-1369 USA
♦
+1.402.323.0702
20
6.8
Configure Encoder for Streaming RTSP
Note:
Settings in the user interface cannot be changed if the unit is currently encoding.
(1)
Return to the user interface.
(2)
If necessary, click the “Stop” button in the “Channel Controls” section of the CH1 tab or the “Stop
All” button in the lower right corner of any screen to stop any current encoding.
(3)
At the CH1 tab, verify the “Video Source” is set to “HDMI” using the dropdown menu.
(4)
Verify “Video Resolution” to “3840x2160” or “follow input”.
(5)
Select the codec you would like to use for your encoding. Both H.265/HEVC and H.264/AVC are
supported. In the pictured example, “Video Codec” is set to “H265(HEVC)” in the dropdown menu.
(6)
Set “Output Format” to “RTSP”.
(7)
Make note of your encoder’s IP address. This can be found in ZFinder or as the URL of the web
browser running the user interface.
(8)
Click the “Start” button.
Figure 12 Channel 1 Tab – RTSP
(5) Change
to “RTSP”
(3) Verify is
“1920x1080” or
“Follow Input”
(1) If necessary, click “Stop”
(6) Click “Start”
(2) Verify
Is “HDMI”
(4) Note value